Softkey
Operating Manual 6175.4760.02 – 01
Description
Open a listbox and use the
knob to select the post-se-
lector mode. Press 'ENT' to
confirm.
The following waveform dependencies apply to the
post-selector:
SECOM-H: The post-selector is always bypassed.
ALE-2G/ALE-3G: SELECTIVE MODE is automatically
changed to SCAN MODE.
This automatism is not reflected on MMI.
Navigate to the subdomain Radio Inventory. The first menu
is the Radio Inventory List menu (see "Menu Radio Inven-
tory (3021)" on p. 3.59).
Navigate to the subdomain Radio Error. The first menu is
the Radio Error List menu (see "Menu Radio Error List
(3011)" on p. 3.55).
The receiver / exciter is part of a broadband system.
Only monitoring access is possible. This softkey is
only available when the radio is connected to a PMU.
Radio Maintenance
Possible Values
SELECTIVE:
Selective in Rx and Tx direc-
tion where possible.
BYPASS:
The post-selector is by-
passed.
SCAN MODE:
Selective in Tx direction,
where possible. It stays selec-
tive if Rx and Tx frequencies
are equal, but enters Rx by-
pass if Rx frequency changes.