Changing The Release Time - R&S M3SR 4100 Series Operating Manual

Software defined radios
Table of Contents

Advertisement

M3SR Series 4100
3.7.2.11

Changing the Release Time

Softkey
3.146
Softkey Type
Listbox
The currently selected release time is dis-
played in the central area.
Changing the Release Time
Description
1. Press 'Release Time' softkey.
2. Select desired time from listbox.
3. Press 'ENT' to confirm.
The release time (= hold time + decay time) is
the time after which the AGC is achieving the
full receiver sensitivity.
It is available for all modulation types except
F3E and F1D. When changing the modulation
mode, the default release times are loaded
once again. So, for global changes, better use
the Fixed Frequency Configuration menu to
change the defaults directly.
Possible values:
25 ms - 150 ms - 500 ms - 1000 ms - 3000 ms
- 5000 ms - 9000 ms
Operating Manual 6175.4760.02 – 01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr4100gMr4100eMr4100xMr4100g-b

Table of Contents

Save PDF