7133 Models 010 And 020 Rack-Mounted Ssa Subsystem - IBM RS/60000 Series Site And Hardware Planning Information

Table of Contents

Advertisement

7133 Models 010 and 020 Rack-Mounted SSA Subsystem

Dimensions
Height
Width
Depth
Weight
Minimum
Maximum
Electrical
Power source loading:
Maximum start-up
Maximum operating
Maximum idling
Power factor
Voltage range (V ac)
Voltage optional (V dc)
Frequency (hertz)
DC Power Supply -48 V dc
(Model 020 only)
Thermal output (Maximum)
Maximum altitude
Temperature Requirements
(See note 2)
Humidity Requirements
(Noncondensing)
Wet Bulb
Noise Emissions*
L
WAd
L
pAm
<L
>
pA
m
Impulsive or prominent
discrete tones
* See "Noise Emission Notes" on page 336 for definitions of noise emissions positions.
1. Each 7133 rack-mounted unit requires an air flow of 2.46 cubic meters/minute (87 CFM). When racks containing
many 7133 units are to be installed together, the following requirements must be met to ensure that the 7133
units are adequately cooled:
v The airflow is in at the front of the rack and out at the back. To avoid moving exhaust air to the intake of
another piece of equipment, racks should be positioned in alternate rows, back-to-back and front-to-front.
v The front of racks should be positioned on floor-tile seams, with a full line of perforated tiles immediately in
front of the racks. Each perforated tile should have an air flow of at least 11.34 m³/min (400 CFM). The
underfloor temperature must be at most 15°C (60°F).
v Where racks are in rows front-to-front or back-to-back, there should be a gap of at least 1220 mm (48 in)
separating the rows.
v To ensure proper air flow within each rack, the rack filler plates must be installed in unused positions. Also, all
the gaps in the front of the racks must be sealed, including the gaps between the 7133 units.
2. The recommended operating temperature is 22°C (72°F) or lower. At lower temperatures, the risk of failure in the
unit is reduced. If the operating temperature is above 22°C (72°F) for long periods of time, the unit will be
exposed to a greater risk of failure from external causes.
171 mm
444 mm
665 mm
36 kg
50 kg
0.657 kVA
0.499 kVA
0.45 kVA
greater than 0.95
100 to 240
240 to 375
50 or 60
-40 to -60
2074 Btu/hr (See note 1)
2135 m (7000 ft.)
Operating
10 to 40°C
(50 to 104°F)
Operating
8% to 80%
27°C (80°F)
Operating
6.15 bels
N/A
48 dBA
No
Chapter 7. Physical Characteristics of the 7100 Series
6.7 in.
(4 EIA units)
17.5 in.
26.2 in.
79 lbs.
110 lbs.
Non-Operating
10 to 52°C
(50 to 125°F)
Non-Operating
8% to 80%
27°C (80°F)
Idle
6.1 bels
N/A
45 dBA
No
269