7025 Deskside 6F1 Series

Dimensions
Height
Width
Depth
Weight
Minimum configuration
Maximum configuration
Electrical
Power source loading typical in kVA
Power source loading maximum in kVA
Voltage range (V ac)
Frequency (hertz)
Thermal output (typical)
Thermal output (maximum)
Power requirements (typical)
Power requirements (maximum)
Power factor
Inrush current³
Maximum altitude⁴
Temperature Requirements
Humidity Requirements
(Noncondensing)
Wet Bulb
Noise Emissions¹
L
WAd
L
pAm
<L
>
pA
m
Impulsive or prominent discrete tones
Clearances
Install/Air Flow²
Service
2
Footprint
1. See "Noise Emission Notes" on page 336 for definitions of noise emissions positions.
2. The amount of space needed by the unit during normal operation is indicated by the footprint dimensions.
3. Inrush currents occur only at initial application of power, no inrush occurs during normal power off-on cycle.
4. A)Dry bulb temperature derating at high altitude: Upper limit temperature must be derated 1.0 deg C per 137 m
of elevation beyond 1295 m above sea level. (1 deg F per 250 ft above 4250 feet). B) Wet bulb temperature
derating at high altitude: Upper limit temperature must be derated 1 deg C per 274 m of elevation beyond 1372m
above sea level (1 deg F per 500 ft above 4500 feet).
5. For systems with FC 6134: 60/150 GB 16-bit 8mm Internal Tape Drive, the maximum operating temperature is
limited. For additional information about this limitation, refer to the following table.
100 to 127 or 200 to 240 (autoranging)
4, 5
Operating
10 to 38°C
(50 to 100°F)
Operating⁴
8 to 80%
23°C (73°F)
Operating
6.1 bels
N/A
43 dBA
No
Front
76mm(3 in)
152mm(6 in)
Install so that it can be moved to an area providing 457 mm (18 in.) on the
front and 457 mm (18 in) on the left side.
Width
585mm(23 in)
610 mm 24.0 in.
483 mm 19.0 in.
728 mm 28.7 in.
70 kg 155 lbs.
95 kg 209 lbs.
0.59
0.86
50 or 60
1920 Btu/hr
2867 Btu/hr
560 watts
840 watts
0.95
70 amps
2135 m (7000 ft.)
Non-Operating
(50 to 110°F)
Non-Operating
Back
Left
51mm(2 in)
956mm(37.7 in)
Chapter 2. Physical Characteristics of Systems
10 to 43°C
8 to 80%
27°C (80°F)
Idle
5.9 bels
N/A
40 dBA
No
Right
51mm(2 in)
Depth
61

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7006 42tEserver pseries7006 42w7007 powerportable n407008 powerstation m207008 powerstation m2a ... Show all