7029 Models 6C3 and 6E3

The Model 6C3 is a rack-mounted server system and the Model 6E3 is a deskside tower system.
Dimensions
Height
Width
Depth
Weight
Minimum configuration
Maximum configuration
Electrical
Power source loading (typical in kVA)
Power source loading (max. in kVA)
Voltage range (V ac)
Frequency (hertz)
Voltage range (V dc)
Thermal output (typical)
Thermal output (max.)
Power requirements (typical)
Power requirements (max.)
Power factor - US, World Trade, Japan
Inrush current²
Maximum altitude³,⁴
Temperature Requirements³, ⁶
Humidity Requirements⁴
(Noncondensing)
Wet Bulb
Model 6C3 Noise Emissions
L
WAd
Model 6E3 Noise Emissions
L
WAd
Install/Air Flow
Service
1. See "Noise Emission Notes" on page 336 for definitions of noise emissions positions. See noise emissions note
4.
2. Inrush currents occur only at initial application of power, no inrush occurs during normal power off-on cycle.
3. The upper limit of the dry bulb temperature must be derated 1°C per 137 m (450 ft.) above 915 m (3000 ft.).
4. The upper limit of the wet bulb temperature must be derated 1°C per 274 m (900 ft. ) above 305 m (1000 ft.).
5. Levels are for a single system installed in a T00 32 EIA rack with the center of the unit approximately 1500 mm
(59 in.) off the floor.
6. For systems with FC 6134: 60/150 GB 16-bit 8mm Internal Tape Drive, the maximum operating temperature is
limited. For additional information about this limitation, refer to the following table.
Rack (Model 6C3)
178 mm (7.0 in)
4EIA Units
437 mm (17.2 in.)
508 mm (20.0 in.)
35.5 kg (78.0 lbs.)
43.1 kg (94.8 lbs.)
Operating
10 to 40°C
50 to 104°F)
Operating
8 to 80%
27°C (80°F)
Operating
1, 5
Operating
1
Maintenance of service clearance will allow proper air flow.
See service clearances for the 7014 T00 Rack
0.30
0.50
100 to 127 or 200 to 240 (auto-ranging)
47 / 63
Not supported
1024 Btu/hr
1536 Btu/hr
300 watts
450 watts
0.95
85 amps (max. at <10ms)
25 amps (max at 10 to 150ms
2135 m (7000 ft.)
6.0 bels
6.1 bels
Chapter 2. Physical Characteristics of Systems
Tower (Model 6E3)
533.0 mm (21.0 in.)
201 mm (7.9 in.)
584 mm (23.0 in.)
35.5 kg (78.0 lbs.)
43.1 kg (94.8 lbs.)
Non-Operating
10 to 43°C
(50 to 109°F)
Non-Operating
8 to 80%
27°C (80°F)
Idle
6.0 bels
Idle
6.1 bels
83