7025 Deskside F30 Series - IBM RS/60000 Series Site And Hardware Planning Information

Table of Contents

Advertisement

7025 Deskside F30 Series

Dimensions
Height
Width
Width with Pedestal
Depth
Depth with Pedestal
Weight
Minimum
configuration
Maximum
configuration
Electrical
Power source loading
(maximum in kVA)
Voltage range (V ac)
Frequency (hertz)
Thermal output
(maximum)
Power requirements
(maximum)
Power factor
Inrush current³
Maximum altitude
Temperature
Requirements
Humidity
Requirements
(Noncondensing)
Wet Bulb
Noise Emissions¹
L
WAd
L
pAm
<L
>
pA
m
Impulsive or
prominent discrete
tones
Clearances
Install/Air Flow²
Service
Install so that it can be moved to an area providing 457mm (18 in.) on the front and 457 mm
(18 in) on the left side.
2
Footprint
1. See "Noise Emission Notes" on page 336 for definitions of noise emissions positions.
2. The amount of space needed by the unit during normal operation is indicated by the footprint dimensions.
3. Inrush currents occur only at initial application of power, no inrush occurs during normal power off-on cycle.
100 to 127 or 200 to 240 (autoranging)
30 amps at 120 V ac, 60 amps at 240 V ac
Operating
16 to 32°C
(60 to 90°F)
Operating
8 to 80%
23°C (73°F)
Operating
5.8 bels
N/A
41 dBA
No
Front
76mm(3 in)
152mm(6 in)
Width
350mm(13.7 in)
620 mm 24.3 in.
245 mm 9.6 in.
350 mm 13.7 in.
695 mm 27.3 in.
745 mm 29.3 in.
30 kg 65 lbs.
50 kg 110 lbs.
0.56
50 or 60
1535 Btu/hr
450 watts
0.8
2135 m (7000 ft.)
Back
Left
51mm(2 in)
Chapter 2. Physical Characteristics of Systems
Non-Operating
10 to 43°C
(50 to 110°F)
Non-Operating
8 to 80%
27°C (80°F)
Idle
5.5 bels
N/A
38 dBA
No
Right
51mm(2 in)
Depth
975mm(38.4 in)
63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7006 42tEserver pseries7006 42w7007 powerportable n407008 powerstation m207008 powerstation m2a ... Show all

Table of Contents