6. COORDINATE MEASUREMENT
6.1 Execution of Coordinate Measurement
Measure the coordinates by entering the instrument height and prism height,
coordinates of unknown Point will be measured directly.
* When setting coordinate values of occupied point, see Section 6.2 "Setting
Coordinate Values of Occupied Station Point".
* When setting the instrument height and prism height, see Section 6.3
"Setting Height of the Instrument" and 6.4 "Setting Height of Target (prism
Height)".
* To set backsight, determine the backsight azimuth or check the known
azimuth, coordinate and distance.
The coordinates of the unknown point are calculated as shown below and displayed:
Coordinates of occupied point: (N0,E0,Z0)
Instrument height :INS.HT
Prism height: R.HT
Vertical distance (Relative elevation):Z(VD)
Coordinates of the center of the prism, originated from the center point of the
instrument: (n,e,z)
Coordinates of unknown point: (N1,E1,Z1)
N1=N0+n
E1=E0+e
Z1=Z0+INS.HT+Z-R.HT
Center point of the instrument (N0, E0, Z0+INS.HT)
56