3.4 Setting of the Vertical Angle Tilt Correction

When the tilt sensor is activated the instrument automatically corrects the
vertical angle for mislevel. To ensure a precise angle measurement the tilt sensor
must be turned on. The tilt sensor display can also be used to fine level the
instrument. If the ("X TILT OVER") display appears the instrument is out of the
automatic compensation range and must be leveled manually to within tolerances.
The instruments compensates the vertical angle reading due to inclination of
the standing axis in the X direction.
When the instrument is on an unstable footing or used during a windy day the
display of vertical angle can be unstable. You can turn off the auto tilt correction
function in this case.
Setting the tilt correction
The instrument memorizes the last setting for this feature. To insure the compensator
is on check this setting before operating the instrument.
For operation procedures refer to 11.2.1.