The window switching speed is slow.
• When both lines are set to through display in the multi-line random trigger mode, the controller's re-
sponse time may be slow.
Remote Operation Tool operation or operation of tools such as the
Communications Command Macro tool is unstable.
• This can occur when there is not enough free application memory space. To free up application
memory space in order to resolve this issue, try deleting processing units to reduce the number of
processing units in the measurement flow.
Software keyboard is not displayed.
• When the keyboard is connected to the sensor controller, the software keyboard is not displayed.
Please input characters with the connected keyboard. During remote operation, if the keyboard is
connected to the PC on the remote control side, the software keyboard will not be displayed.
The image will not be displayed when remeasuring saved images.
• You may be using the through image mode in the image display pane on the used layouts. If you are
used the through image mode in the image display pane, the image will not be displayed. Check the
image mode for all used and unused image display pane.
Refer to 8-3 Arranging Windows [Layout Functions] on page 8 - 12 and check the image display
mode specifications for all 24 image display panes.
11-2-3

For Measurement

Display is not updated.
• Measurement is given priority when the STEP signal input interval is short or continuous measure-
ment is being performed. As a result, the measurement results (overall judgment, image, individual
judgment in the flow display, detailed results) may not be updated. When continuous measurement
ends, the measurement results for the final measurement are displayed.
The measurement NG (image mismatch) error will result when con-
necting a monochrome camera.
• Immediately after performing such operation as starting up the Sensor Controller, changing scenes,
and clearing measurement results, there will be no input image. If you edit the settings or press the
OK button in the Properties Dialog Box with no input image, the error will occur at the next measure-
ment.
• If you open the Properties Dialog Box and click the OK button to close the dialog box with no input
image, the settings will automatically switch to the factory default settings for the color cameras. If
FH/FHV Series Vision System User's Manual (Z365-E1)
11 What to Do!
11
11 - 11