4 Setting the Controller
USB connection
(Maximum cable length: 5 m)
FH-MT12
Analog RGB
Use an RS-232C cable connection in the following cases.
• The Touch Panel Monitor (FH-MT12) and the FH series Sensor Controller are more than 5 m apart.
• All the USB ports of the FH series Sensor Controller are used for other I/O connections, and thus
there is no available USB port for the Touch Panel Monitor (FH-MT12) connection.
RS-232C connection
(Maximum cable length: 10m)
FH-MT12
Analog RGB
For monitor cable of video input or communication cable of Touch Panel, refer to the followings:
• Connection cable for FH-MT12
Cable name
Monitor cable
Touch Panel cable
When connect the monitor cable, Sensor Controller recognizes Touch Panel Monitor automatically,
and then start to display.
Additional Information
When use only monitor function of Touch Panel Monitor (FH-MT12), confirm the followings:
• No limitation of software version of FH series Sensor Controller.
• Not cable for Touch Panel Monitor, but only monitor cable for video.
The setting steps for the touch panel monitor and the communication module are as follows.
4 - 8
Type B
Touch Panel cable(USB): FH-VUAB
D-Sub
Monitor cable: FH-VMDA
USB
D-Sub
Monitor cable: FH-VMDA
RS-232C
Type
DVI-RGB converter
cable
USB
RS-232C
Connect to the optional FH series
Sensor Controller' s USB port
Type A
DVI-A
DVI-I
FH series Sensor Controller
FH series Sensor Controller
DVI-A
RS-232C
DVI-I
Cable length
Model
2 m
FH-VMDA 2M
5 m
FH-VMDA 5M
10 m
FH-VMDA 10M
2 m
FH-VUAB 2M
5 m
FH-VUAB 5M
2 m
XW2Z-200PP-1
5 m
XW2Z-500PP-1
10 m
XW2Z-010PP-1
FH/FHV Series Vision System User's Manual (Z365-E1)
Minimum bend ra-
dius
36 mm
25 mm
59 mm