Error message
Memory is becoming insufficient.
According to the setting, memory
shortage may occur.
Overcurrent was detected. Turn
OFF the power supply and remove
the USB device to restart.
You need to format the disk in drive
*: before you can use it. Do you
want to format it?
Add to unit is failed. Insufficiency
memory may be occurred.
The free capacity of RAMDisk is in-
sufficient. If nothing is done, meas-
urement cannot be performed cor-
rectly.
Increase free capacity in RAMDisk.
Region size exceeds. Please nar-
row region.
Logging error
The Logon to Network Server
screen is displayed.
FH/FHV Series Vision System User's Manual (Z365-E1)
Troubleshooting
The free application memory has decreased.
Memory may become insufficient, or an error may occur in operation
mode switching.
Re-configure the inspection flow to reduce memory consumption.
The amount of memory used and free data memory can be checked
from the menu of Memory Consumption Monitor on the Measurement
Management Bar or the system menu.
Refer to 3-4 Checking the Memory Consumption and Percentage of
Memory Used on page 3 - 28 and 3-3 Checking System Information
[System Information] on page 3 - 24.
Check the following points.
There may be a problem with the USB device. Stop the current process
and then turn OFF the Sensor Controller. Remove the USB device and
restart the Sensor Controller.
The power consumption of the USB device may exceed the power sup-
ply capacity of the Sensor Controller. Stop the current process and
then turn OFF the Sensor Controller. Provide power to the USB device
by using external power source, i.e. AC adapter. Then try to launch the
Sensor Controller.
The external storage which is inserted to the drive may have an error.
Select Cancel and check the external storage with your PC.
Application memory is insufficient, Reduce the number of processing
units of measurement flow.
The amount of memory used and free data memory can be checked
from the menu of Memory Consumption Monitor on the Measurement
Management Bar or the system menu.
Refer to 3-4 Checking the Memory Consumption and Percentage of
Memory Used on page 3 - 28 and 3-3 Checking System Information
[System Information] on page 3 - 24.
Clean up the content of RAMDisk to increase free space. If this error oc-
curs even though enough free space is available, Scene group data may
be too large. Review the inspection flow.
There are restrictions as to what can be set up based on the camera and
processing items being used. Please adjust the region size so that the re-
gion is not too large.
Image logging failed due to insufficient memory at the save destination.
The error message disappears after 10 s.
Delete unneeded files in the save destination or prepare a new USB
disk.
Logging fails in a measurement at the Sensor Controller start-up, a rec-
ognition delay of external storage might have occurred at the Sensor
Controller start-up. Use the Device Information Storage Tool.
If Use scene name as folder names is checked in the logging setting, log-
ging error occurs if you use \ / : , ; * ? " < > | as the scene name.
The connection was cut off based on the idling / session time set on the
network logging destination PC.
At the command prompt on the PC, enter the following:
net config server /autodisconnect:-1
Then disable the automatic disconnection setting.
11 What to Do!
11
11 - 7