5 Creating Measurement Scenes
1
Click the Edit flow tab. Display the Edit flow tab screen.
For more details, refer to Edit Flow Tab Screen on page 5 - 15.
2
On the Unit list (flow), select a processing unit to be load.
3
In the Edit flow button area, click Load Unit.
Additional Information
The following operation also enables processing units to be loaded.
• Click Load Unit from Edit flow in the Menu bar.
• Right-click a processing unit on the Unit list (flow) and then click Load Unit on the displayed
shortcut menu.
The FileExplorer dialog box is displayed.
For more details, refer to 3-2-3 Selecting Files and Folders on page 3 - 9.
4
Set the load destination and file name to be loaded, and then click OK.
The loaded processing unit is inserted to the selected position on the Unit list (flow).
Switching Processing Unit Measurement ON/OFF
The measurement function can be enabled and disabled per processing unit. A processing unit that
the function has been disabled cannot perform the measurement until the function is enabled.
Precautions for Correct Use
Be sure to enable the measurement function for the image input processing unit with the unit
No. 0 before use.
Additional Information
• Turning on or turning off the measurement function for a folder, a parallelization processing
unit, or a parallelized task processing unit turns on or off the measurement for all processing
units for the folder, the parallelization processing unit, or the parallelized task processing unit.
• When ON is set for Parallel Execute in Operation mode setting in the system settings,
turning the measurement function setting ON/OFF for a processing unit may greatly change
the processing time. In this case, use parallelization processing items to parallelize the meas-
urement flow instead of using automatic parallel processing.
For details, refer to4-4-2 Parallel Processing on page 4 - 27.
• When the measurement function for a processing unit in a conditional branch destination has
been disabled, the measurement will be performed from a processing unit set to on in the fol-
lowing branch destination processing units.
• Overall judgement result of the processing units that are set in the folder is displayed in the
folder unit. However, if a Conditional branch is set to branch outside the folder, the overall
judgement result of the processing units set in the folder unit will always display as OK.
1
Click the Edit flow tab. Display the Edit flow tab screen.
For more details, refer to Edit Flow Tab Screen on page 5 - 15.
2
On the Edit flow tab screen, select a processing unit on the Unit list (flow) that its measurement
function is to be enabled or disabled.
5 - 30
FH/FHV Series Vision System User's Manual (Z365-E1)