4 Setting the Controller
Precautions for Correct Use
The settings of the Multi-line Random-trigger Mode Settings apply only to the FH series Sen-
sor Controller.
l Functional Limitations of Multi-line Random-trigger Mode
Keep the following points in mind when using Multi-line Random-trigger Mode.
Item
Processing time
Number of Cameras
Error messages
Saving data in the Con-
troller
Save folder for captured
images
Date-time setting, lan-
guage setting, operation
mode setting and Net-
work drive setting.
View
Communi-
cations
STEP setting
4 - 20
If the processing load for multiple lines is high, there may be fluctuation in
measurement times.
If data logging for multiple lines is to the same drive, measurement times may
become longer.
The maximum number of Cameras is 8 for all lines.
Error messages are the same for lines 0 to 7. If an error occurs on any of the
lines, an error message is displayed and the ERROR signal is turned ON.
To save data in the Controller, the data must be saved separately for each line.
When you click Capture on the Measurement Manager Bar, captured images are
always saved to the folder that is specified for line 0.
These settings can be set only for line 0.
Images can be displayed simultaneously for all lines. Use layout modification to
set the display position and size for the Main Window for each line.
Parallel
Parallel communications can be set only for line 0. The settings for line 0 are
applied to lines 1 to 7.
Refer to Table 1 for details on the differences between parallel I/O and parallel
terminals.
Normal
RS-232C can be set only for line 0.
(RS- 232C/
Lines 1 to 7 cannot be used.
422)
Normal
To use Ethernet, use a different port number for each line.
(Ethernet)
The IP address for the Controller cannot be set for lines 1 to 7 (the IP address
for line 0 is used).
PLC Link
RS-232C can be set only for line 0.
(RS-232C/
Lines 1 to 7 cannot be used.
422)
PLC Link
To use Ethernet, use a different port number for each line.
(Ethernet)
The IP address for the Controller cannot be set for lines 1 to 7 (the IP address
for line 0 is used).
EtherNet/I
To use EtherNet/IP, use an EDS file that matches the line to be used.
P
Specify different I/O memory addresses for the sending area and receiving
area for line 0 and for lines 1 to 7.
The value of the STEP signal filter for the most recently set line is applied to all
lines.
FH series:
FH-1000/2000/3000/5000 series
FH/FHV Series Vision System User's Manual (Z365-E1)