4 Setting the Controller
.
2
Click a camera number to set the delay between STEP-cameras and then specify the delay
count value.
Item
Delay between
STEP-cameras
Transmission
speed
4 - 40
Set value
[Factory default]
•
Sets the delay time from when the STEP signal is received to
-4 to 511
[0]
when exposure begins for the selected Camera.
•
(1 count is 30
Delay time of FH series Sensor Controller: When using
μs)
cameras other than FH-S£05R, the time displayed for
STEP-camera delay time is (STEP-camera delay counts ×
30 μs + 122 μs) + 120 μs.
When using the FH-S£05R camera, the time displayed for
STEP-camera delay time is (STEP-camera delay counts ×
30 μs + 122 μs) + 470 μs.
When using the FH-S£21R camera, the time displayed for
STEP-camera delay time is (STEP-camera delay counts ×
30 μs + 122 μs) + 1123 μs.
•
When you connect a camera that supports High speed mode
[Standard]
•
High speed
using a camera cable shorter than 5m, image input time can
be shortened by selecting High speed for frame rate.
For details about frame rate values, refer to the Instruction
manual for the Camera.
The following cameras support High speed:
•
FH-SC02/FH-SM02
•
FH-SC04/FH-SM04
•
FH-SC12/FH-SM12
•
FH-SCX/FH-SMX
•
FH-SCX05/FH-SMX05
•
FH-SCX12/FH-SMX12
•
FH-SC21R/FH-SM21R
Description
FH/FHV Series Vision System User's Manual (Z365-E1)