Value Input Window (Mdi_Numbox.dll) - Omron FH Series User Manual

Vision sensor
Hide thumbs Also See for FH Series:
Table of Contents

Advertisement

8 Setting Windows
The usage method is to specify an event number of 480 for the RaiseOptionEvent relationship, and
20000 for the parameter to display the message box.
Example:
–––––––––––––––––––––––––––––––––––––––––––––
SetGlobalData "MsgBoxCaptionText", "Title character string"
SetGlobalData "MsgBoxMessageText", "Message character string"
Set GlobalData "MsgBoxButtons", "OK"
RaiseOptionEvent 480.20000
–––––––––––––––––––––––––––––––––––––––––––––
8-3-22

Value Input Window (MDI_NumBox.dll)

Window part to processing item parameters and macro variable numerical values.
This comprises the following elements.
• Numerical value input box
Details that can be set are as follows.
Item
Data settings
Data type
Unit
Data identifier 0
8 - 54
Setting value
[Factory default]
-
Configure settings for numerical input data.
[Unit data]
Selects the data type to input numerical value.
Scene variable
Global data
System data
System variable
-
This item is available when Unit data is selected in Data type.
Sets the unit to set the numerical value input data using a unit
number or unit label character string using up to 32 characters.
Only single-byte alphanumeric characters as well as _&#$@ can
be input.
PanDA
This item is available when System data is selected in Data type.
Selects the identifier name 0 of the system data from the combo
Macro_IO
box.
Description
FH/FHV Series Vision System User's Manual (Z365-E1)