l Multi-input + Parallel processing OFF
STEP
READY
BUSY
Sensor Controller
Processing
After checking if READY is ON and BUSY is OFF, turn ON the STEP (STEP1).
1.
When STEP turns ON, READY turns OFF and BUSY turns ON.
Camera image (2 Camera image input FH) is input.
2.
After READY turns OFF and BUSY turns ON, turn OFF the STEP.
Since multi-input mode is selected for this example, READY turns ON after completing Camera
Image Input (2 Camera image input FH).
3.
After completing Input image (2 Camera image input FH), measurement processing (3 Search) is
executed.
After checking if READY is ON, turn ON the STEP (STEP2).
When STEP turns ON, READY turns OFF.
4.
Since multi-input mode is selected for this example, Input image (5 Camera Image Input) is per-
formed in the same way as 2 Camera image input FH.
5.
After READY turns OFF, turn OFF the STEP.
6.
After completing Input image (5 Camera image input FH), READY turns OFF.
Since Parallel processing is disabled, 6 Search measurement processing is executed after 3
7.
Search measurement processing is completed.
The measurement is performed according to the flow setting.
After measurement processing is completed, BUSY turns OFF.
8.
Display processing (11 Result Display) is performed.
FH/FHV Series Vision System User's Manual (Z365-E1)
STEP1
STEP2
1
2
3
4 5
6
Input image
Input image
2.Camera
5.Camera
Image Input FH
Image Input FH
Measurement
processing
3.Search
7
Measurement
Measurement
Measurement processing
processing
processing
9.Conditional
8.Calculation
6.Search
Branching
10 Advanced Usage
8
Measurement
Display
processing
processing
11.Result
10.Search
Display
10
10 - 25