10 Advanced Usage
●Vision Master Calibration (Homing operation selection is Disabled.):
External device
1: Moves to the axis
Repeats processing within
this frame until calibration
complete flag is ON (1).
Moves only each axis of next axis
movement amount when calibration
complete flag is OFF (0).
4: Moves only each axis of
●PLC Master Calibration:
• Standard Mode:
The numbers in parenthesis are the external reference numbers that are used when commands are
executed for the PLC Master Calibration processing unit.
Refer to External Reference Table under PLC Master Calibration in the Vision System FH/FHV
Series Processing Item Function Reference Manual (Cat. No. Z341).
10 - 58
PLC
position when
Calibration is started.
Response that
movement is completed.
•
•
next axis movement
amount
Response that
movement is completed.
FH/FHV
2: Clear the measurement
results.
Response that clear
processing is completed.
3: Measurement Command
Outputs data
Next axis movement amount
(by each axis of external device)
Calibration complete flag
FH/FHV Series Vision System User's Manual (Z365-E1)
3.1: Measurement