Troubleshooting - Omron FH Series User Manual

Vision sensor
Hide thumbs Also See for FH Series:
Table of Contents

Advertisement

1
Click Close.
2
The following Confirm dialog screen will display.
After verifying that the copied/cleared setting data is correct, click the OK button.
The sensor controller will automatically restart.
Precautions for Correct Use
When copying system settings, verify the Communication settings for each line after restarting
the sensor controller. Depending on the Communication settings selected, if Lines 0-7 have the
same settings, the sensor controller may not be able to communicate with other devices.
9-8-4

Troubleshooting

A list of some common errors that may occur when using the Line Maintenance tool.
Problem
An error message dis-
plays after clicking the
Apply button.
Failed to apply changes.
Failed to access file due
to insufficient memory.
FH/FHV Series Vision System User's Manual (Z365-E1)
Cause
The external storage de-
vice is not connected.
There is insufficient free
memory available in the
external storage device.
9 Saving/Loading Data
Action
Connect an external storage device
Use the Copy/Clear function after checking Apply
immediately
Re-connect an external storage device with more
memory capacity.
Delete un-needed files in the external storage de-
vice to free up space.
Disconnect the external storage device and use the
Copy/Clear function after checking Apply
immediately.