Removing the Developer and Fixer Drain Valves

IMPORTANT
For this procedure the processor must
be deenergized. See page 1-6. In
addition, the TOP COVER, both SIDE
ACCESS PANELS, and the
FEED-END, MIDDLE ACCESS PANEL
must be removed from the processor.
See pages 1-3 through 1-5 for
instructions, if necessary. Also make
sure that the water supply to the
processor is shut off for this procedure.
[1]
Drain the DEVELOPER and FIXER TANKS by
opening the DEVELOPER and FIXER DRAIN
VALVES on the FEED END of the processor.
[2]
Remove the HANDLE from the DEVELOPER
or FIXER DRAIN VALVE ASSEMBLY.
[3]
Remove the CLAMP and CAP from the
DEVELOPER or FIXER AUXILIARY DRAIN.
636739
WASH OVERFLOW
FIXER
and DRAIN
FIXER
DRAIN
AUXILIARY
VALVE
DRAIN
POWER
DEVELOPER
DRAIN VALVE
DEVELOPER
AUXILIARY
DRAIN
Figure 5-20 Opening the Developer and
Fixer Drain Valves
FIXER OVERFLOW
and DRAIN
WATER
INLET
DEVELOPER
OVERFLOW
and DRAIN
H108_0004CCA
H108_0004CA
5-23