[11]
Adjust the SWITCH PLATE ASSEMBLY:
(a)
Loosen the 2 SCREWS.
(b)
Move the SWITCH PLATE ASSEMBLY down, approximately 2.5 mm (0.100 in.).
(c)
Wait 12 seconds.
(d)
If the REPLENISHER PUMPS begin operating, tighten the 2 SCREWS and continue with Step 12.
(e)
If the REPLENISHER PUMPS do not begin operating, repeat Step 11.
[12]
Remove the adhesive tape and pull the FILM TOOL away from the DETECTOR ROLLERS. The
REPLENISHER PUMPS will stop.
The time required to stop the REPLENISHMENT PUMPS corresponds with the amount of time
the FILM TOOL remained under the ACCUMULATOR LEDs.
[13]
Release the NON-DRIVE SIDE MAGNET SWING ARM.
[14]
Repeat Steps 6-13 to adjust the NON-DRIVE SIDE ENTRANCE DETECTOR SWITCH.
NON-DRIVE SIDE
MAGNET
SWING
ARM
RESTRAINER
DETECTOR
ROLLER
6-6
NOTE
Figure 6-5 Adjusting the Switch Plate Assembly
SCREW (2)
SWITCH PLATE
ASSEMBLY
ACCUMULATOR LEDs
REPLENISHMENT PUMPS
H108_0166DCA
H108_0166DA
636739