Removing the Blower Assembly

IMPORTANT
For this procedure the processor must
be deenergized. See page 1-6. In
addition, the DRIVE SIDE ACCESS
PANEL must be removed from the
processor. See pages 1-3 through 1-5
for instructions, if necessary.
[1]
Loosen the SCREW and WASHER to remove
the BLOWER MOTOR COVER from the
BLOWER DRIVE MOTOR.
[2]
Remove the 3 MOUNTING BOLTS from the
BLOWER ASSEMBLY and BLOWER DRIVE
BELT.
[3]
Remove the BLOWER ASSEMBLY.
[4]
Loosen the 2 SETSCREWS to remove the
BLOWER DRIVE BELT PULLEY from the
BLOWER ASSEMBLY.
[5]
Install the BLOWER DRIVE BELT PULLEY
onto the new BLOWER ASSEMBLY.
[6]
Install the new BLOWER ASSEMBLY using
the 3 MOUNTING BOLTS removed Step 3.
[7]
Align the BLOWER DRIVE MOTOR and the
BLOWER DRIVE BELT PULLEYS.
[8]
Install the BLOWER DRIVE BELT.
[9]
Adjust the position of the BLOWER DRIVE
MOTOR to obtain the correct tension of the
BLOWER DRIVE BELT.
Correct tension is achieved when the
BLOWER DRIVE BELT does not make
loud noises when you energize the
processor. This step requires that you
energize the processor in order to test
for correct tension, and then
deenergize the processor to correct the
tension.
[10]
Install the BLOWER MOTOR COVER.
4-2
WASHER
BLOWER
DRIVE
BELT
PULLEY
BLOWER
ASSEMBLY
MOUNTING
BOLT (3)
Figure 4-1 Removing the Blower Assembly
BLOWER
SCREW
MOTOR
COVER
BLOWER
DRIVE
BELT
BLOWER
DRIVE MOTOR
H108_0072CCA
H108_0072CA
636739