[5]
Energize the processor by moving the MAIN CIRCUIT BREAKER, CB1, on the CONTROL PANEL to the
''I'' position.
[6]
See the Operator Manual for the flowchart of menus leading to Diagnostics.
• If you have a LAPTOP COMPUTER, enter the Diagnostics Mode and energize the DRIVE MOTOR.
• If you do not have a LAPTOP COMPUTER, and cannot enter the Diagnostics Mode—
• Remove the TOP COVER of the processor.
• Install a JUMPER, Special Tool TL- 4413, into P/J 29.
• Insert a sheet of waste film into the ENTRANCE ROLLER to activate the transport system.
[7]
Adjust the 4 SETSCREWS in the DRYER DRIVE ASSEMBLY until the DRIVE BELT remains on the
center of the DRYER DRIVE ROLLER.
[8]
Wait for the DRYER to attain its operating temperature.
[9]
When the DRYER has attained its operating temperature, again check that the DRIVE BELT remains on
the center of the DRYER DRIVE ROLLER.
[10]
Tighten the 2 SCREWS loosened in Step 4.
[11]
Again check that the DRIVE BELT tracks on the center of the DRYER DRIVE ROLLER. If it does not,
repeat Steps 4, 7, and 10.
[12]
If you are currently in the Diagnostics Mode, exit Diagnostics.
[13]
Remove the JUMPER used in Step 6 from CONNECTOR P/J 29.
[14]
Install all parts removed in previous steps.
4-18
The DRIVE BELT will track to the higher side of the ROLLER.
Be sure not to over tighten the screws.