Open all the DRAIN VALVES on the FEED
END of the processor.
[7]
Using a HOSE, thoroughly rinse the inside of
the processor TANKS with water.
[8]
Close all the DRAIN VALVES.
[9]
Install all the RACKS.
[10]
Fill the REPLENISHMENT TANKS with clean
water.
[11]
Energize the processor by moving the MAIN
CIRCUIT BREAKER, CB1, to the ''I'' position.
[12]
Using the DISPLAY PANEL, select ''Tank
Fill.'' For more instructions about selecting
menu options on the control panel, see the
Operator Manual. The tanks will fill
automatically.
[13]
Allow the recirculation and transport cycles to
complete their cycles.
[14]
Open all the DRAIN VALVES and drain the
TANKS.
[15]
Repeat the previous 3 steps to be sure that
all the System Cleaner is removed.
[16]
Deenergize the processor by moving the
MAIN CIRCUIT BREAKER, CB1, to the ''O''
position.
[17]
Clean any debris from the DRYER AIR
TUBES and ROLLERS by rinsing them with
warm water.