3.2. Power Unit Installation

3.2.1. Installation for E-Drive PLUS 20", 22", and 24" Fixed Axle Models
Required tools:
10 mm and 17 mm sockets, socket wrench, and torque
wrench
(1)
Right Drive Unit Installation
1
Install the clamp bracket for the right unit to
the E-Drive PLUS unit. Fit the projections on
the unit into the slots in the clamp bracket.
(The standard slots are Nos. 6, 7, 8, and 9.)
2
While keeping the clamp bracket and right
unit in this condition, install the unit to the
wheelchair frame. Fit the back pipe of the
wheelchair frame between the post and
stopper of the clamp bracket.
3
Temporarily tighten the axle using the nut
(tightening torque: approximately 5 Nm) so
that there is no looseness in the axle.
4
Move the stopper so that there are no gaps
between the clamp bracket post, frame,
and stopper, and then tighten the stopper
bolt.
Tightening torque: 11 to 15 Nm
5
Tighten the axle mounting nut.
Tightening torque: 40 to 50 Nm
(2)
Left Drive Unit Installation
Install the left unit in the same way as the right unit.
When the E-Drive PLUS unit is installed, the unit and the wheelchair frame must not interfere with
each other. When installing the width adjustment washers to the shaft in order to prevent interfer-
ence, use up to 3 washers per side.
(3)
Angle Adjustment
To adjust the angle 30°, shift the clamp bracket slots by 1 projection on the unit.
NOTICE
3