Driving Parameters ~Free Mode~ Setting Method - decon E-Drive PLUS Service Manual

Hide thumbs Also See for E-Drive PLUS:
Table of Contents

Advertisement

6.3. Driving Parameters ~Free Mode~ Setting Method

In the Free Mode, each of the following 9 parameters can be set individually.
Item
Description
P1
Forward Speed
P2
Backward Speed
P3
Turning Speed
Straight-line
P4
Acceleration
Straight-line
P5
Deceleration
P6
Turning Acceleration
Joystick Valid Range
P7
(Sensitivity)
P8
Joystick Filter
P9
Torque Limit
PA
Joystick Dead Zone
Joystick Input
Pb
Direction Selection
Note: Bold characters indicate the default settings.
Purpose of Operation
[Preparation]
[1]
Prepare to set the
parameters.
[Start Operation]
[2]
Start setting the param-
eters.
Meaning of Speed Level Indication Position
1
Low Speed
Medium Speed
(30%)
(60%)
Low Speed
Medium Speed
(30%)
(40%)
Medium
Low Speed
Speed
Slow
Standard
Standard
Slow
Slow
Standard
Narrow
Normal
Slightly
Insensitive
Insensitive
High Limit
Low Limit
(45 kg)
(90 kg)
Narrow
Standard
(50% of
(100%)
Standard)
Front/Back Re-
Standard
versed
Operation Method
Horn switch
Speed switch
Power switch
2
3
Medium to
High Speed
(80%)
High Speed
(50%)
High Speed
Quick
Quick
Quick
Wide
Standard
No Limit
(120 kg)
Slightly Wide
(150% of
Standard)
Left/Right
Reversed
Stop the wheelchair in a stable
state, engage the parking brake,
and power OFF.
With the speed switch raised, turn
on the power switch while pushing
the horn switch.
The entire LCD will light up for
approximately 1 second, and you
will hear a long buzzer.
Once the buzzer beeps, release
your hand from the switch.
4
5
High Speed
(100%)
Wide
Very Wide
(200% of Stan-
(300% of Stan-
dard)
dard)
Both Reversed
Flashing
Parameter Status during Operation
and Its Meaning
Off
All lit
Parameter that is currently being set
blinks
6
65