Figure B-4 Placement of LaserFlow Ex with remote
ultrasonic sensor
Note
If the stream level is less than 3" (7.62 cm) when using the
LaserFlow Ex with built-in sensor, ensure the Adaptive Focus
option is active Figure B-3.
More than 3"
Note
If the laser and ultrasonic measuring points differ at the stream
level by more than 3" (7.62 cm), the remote ultrasonic sensor
must be used, Figure B-4.
TIENet™ 360 LaserFlow Ex™ Velocity Sensor
Appendix B Installation Checklist