TIENet™ 360 LaserFlow Ex™ Velocity Sensor
Section 2 Preparation and Installation
2-22
6. Turn the locking handle clockwise until it locks the sensor
in place.
7. Using the bubble level on top of the sensor as a guide,
adjust the carrier by loosening the appropriate bolts in the
sensor carrier clamp so that the bubble in the level falls
within the concentric rings.
8. Turn the laser on to make final adjustments so that the
laser beam hits the flow stream at the exact center of the
pipe (refer to Section 3.4 for Signature or Section 4.3 for
2160).
Note
Additional assistance in adjusting the sensor's position may be
obtained by activating and observing the 360 X-Axis (roll) and
360 Y-Axis (pitch) parameters.
9. Following final adjustments, ensure that all mounting
bracket fasteners are tightened.