Recommended Essential Parameters; Site Conditions - Teledyne TIENet 360 LaserFlow Ex Installation And Operation Manual

Velocity sensor
Hide thumbs Also See for TIENet 360 LaserFlow Ex:
Table of Contents

Advertisement

B.4 Recommended
Essential Parameters
B.5 Site Conditions
Figure B-1 Do not install LaserFlow Ex with built-in
sensor in a free-flowing outfall or in a drop
manhole.
TIENet™ 360 LaserFlow Ex™ Velocity Sensor
The following basic parameters are used in almost every mea-
surement site.
In the 2160, parameters are activated in the Jump to Measure-
ments tab.
In the Signature, parameters are activated by going to Hardware
Setup > Configure Measurements.
360 Distance
360 Velocity
360 Y-Axis
360 Doppler Power
360 Air Temperature
360 Sense Voltage
After programming, Retrieve Data to download initial diagnostic
data, to verify that this data will be available if/when needed.
LaserFlow Ex with Built-in Sensor: When using the
LaserFlow Ex module with the attached sensor, never install the
LaserFlow Ex in a free-flowing outfall or in a drop manhole (see
Figure B-1).
Appendix B Installation Checklist
360 Level
360 X-Axis
360 Ultrasonic Signal
360 Case Temperature
Flow Rate
For recommended parameters
B-5