Wieland samos PRO Manual page 113

Compact-gateways
Table of Contents

Advertisement

The content of the data blocks can be freely selected, but has been preconfigured as follows in the
samosPLAN  6 :
Table 77: Predefined content of input data block 1–5 of the SP-PROFIBUS-DP module
Data block 1
Output data block
Byte 0
Input values for
Module 0 (I1..I8)
Byte 1
Input values for
Module 0 (I9..I16)
Byte 2
Input values for
Module 0 (IQ1..IQ4)
Byte 3
Output values for
Module 0
(Q1..Q4,IQ1-IQ4)
Byte 4
Direct data
(Off) 0
Byte 5
Direct data
(Off) 1
Byte 6
Direct data
(Off) 2
Byte 7
Direct data
(Off) 3
Byte 8
Direct data
(Off) 4
Byte 9
Direct data
(Off) 5
Byte 10 Direct data
(Off) 6
Byte 11 Direct data
(Off) 7
Length
12 bytes
Start
1
address
Detailed information about the content of the process diagram may be found here: Data transferred
to the network (network input data sets [ch. 3.2, p. 19]).
Delete any bytes not required
You can delete bytes pre-allocated by samosPLAN  6 that you do not require by clicking on them with
the mouse.
 Launch samosPLAN  6 .
 Read in the hardware configuration, including the PROFIBUS-DP gateway.
Instructions: Software manual, chapter "Connecting to the safety controller"
 Switch to the Gateway view.
 Click on the byte you do not need and wish to delete.
 Click on the Delete icon in the command bar.
You will find further information about how to configure the process diagram here:
Wieland Electric GmbH | BA000970 | 07/2019 [9855]
Data block 2
Data block 3
Output data block
Output data block
Input values for
Output values for
Module 1
Module 1
Input values for
Output values for
Module 2
Module 2
Input values for
Output values for
Module 3
Module 3
Input values for
Output values for
Module 4
Module 4
Input values for
Output values for
Module 5
Module 5
Input values for
Output values for
Module 6
Module 6
Input values for
Output values for
Module 7
Module 7
Input values for
Output values for
Module 8
Module 8
Input values for
Output values for
Module 9
Module 9
Input values for
Output values for
Module 10
Module 10
Input values for
Output values for
Module 11
Module 11
Input values for
Output values for
Module 12
Module 12
12 bytes
12 bytes
13
25
PROFIBUS DP gateway
Data block 4
Data block 5
Output data block
Output data block
Not allocated
Not allocated
Not allocated
Not allocated
Not allocated
Not available
Not allocated
Not allocated
Not allocated
Not allocated
Not allocated
Not allocated
Not allocated
Not allocated
Not allocated
12 bytes
2 bytes
37
49
113