Accessing the Program Menu:
There are several settings available in the programming menu. Care should
be used when selecting or changing a program setting.
• Press the Menu Set-Up (Up and Down arrows) buttons simultane-
ously for three seconds. When the control panel beeps, release the
buttons immediately.
• The programming menu is successfully entered when Search
Sense appears on the screen. Use the Up or Down arrows to scroll
the programming menu.
• The Settings button will change the value or option.
• Press the Menu Set-Up buttons to exit the programming mode.
Shunt Selection - When programming the shunt option, the Master inverter
remote in the monitor panel will be programmed "External Shunt: This
Inverter." The Slave inverter adjacent to the monitor panel will be programmed
"External Shunt: Other Inverter." The Slave remote will then be a used as a
display only. All AC and DC voltage and current values are viewed through
the Master remote.
Auto Gen Start - The Auto Gen Start feature can be programmed to start
the generator from either a specific voltage or a percentage of state of charge.
The Auto Gen Start feature can be programmed to stop the generator at a point
of the charge cycle or a percentage of state of charge. If the Auto Gen Start
feature is programmed to start or stop the generator from a specific state of
charge, the voltage setting of Fuel Gauge Cutout will affect at what point the
generator starts or stops. For example: If the Fuel Gauge Cut-out voltage is set
to 11.8 Volts with the generator set to start at 80% SOC (state of charge), actual
voltage when the generator would start would be approximately 12.5 Volts.
Battery Type - Charge voltage is automatically selected when programming
the battery type of the Master remote in the programming menu heading
"Battery Type."
Battery Type: Select "Battery Type: AGM" - This setting uses a lower
charge voltage than the Liquid Lead Acid setting.
Battery Capacity - The amount of time in the Bulk and Absorb charge
cycles are automatically selected when programming the Battery Capacity of
the Master remote. In the programming menu under Battery Capacity: select
Battery Capacity 1000Ahr.
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
N A V I G A T O R 2 0 0 3
Electrical Systems - House
External Shunt:
This Inverter
External Shunt:
Other Inverter
Battery Type
AGM
Battery Capacity
1000Ahr