7. Press the DOWN button on the Menu Items button, "End Quiet
Time h:m" will display. End Quiet Time is the time you want the
generator to begin operation. Using the Set Point buttons to set
the hour and minute (24 hour clock) will end quiet time.
NOTE: If desired the quiet time may be disabled. Set the Start and
End Quiet Times to the same hour and minute.
The next set of instructions covers many variables to program the starting
or stopping events of the generator. Many different starting conditions, length
of operation or stopping conditions are available. If in doubt about changing
any settings, the factory default settings are average settings and will work in
many situations.
WARNING: Use caution when programming the automatic genera-
tor start function. When this feature is enabled the generator may
start at any time. Disable this feature when performing service to
the generator or when stored in an enclosed building.
Gen Auto Start Setup:
8. Press the red and green buttons simultaneously to continue the
generator autostart programming. Heading number "9 Inverter
Setup" should appear.
9. Press the Menu Headings DOWN button to scroll to heading
number "12 Gen Auto Start" setup. Press the Menu Items DOWN
button to advance through the next set of variables. Read all
options first before setting any values of the Menu Items in Menu
Heading number "12."
10. Press the Set Point buttons to change the settings of a Menu Item.
Menu Items in Menu Heading 12 Gen Auto Start Setup:
Set Load Start Amps AC - Starts the generator when the AC current on
the pass through relay of the inverter meets or exceeds the preset number of
amps. For example: Setting the preset number of amps to 15 when hooked to a
20 Amp service starts the generator when the total current exceeds 15 Amps on
the pass through relay.
Set Load Start Delay Min - This is the time delay period used with Set
Load Start amps AC menu item. Example; setting the time period to 00:00
starts the generator immediately when the total number of amps exceeds the
setting of menu item Set Load Start amps AC.