Battery Temp/Comp Volts DC - Displays the bulk voltage setting
in the menu item Set Bulk Volts DC under the menu heading
Battery Charging number 10. Actual charge voltage will differ
depending on ambient temperature. This is due to battery temperature
compensation.
Inverter Volts AC - Displays the inverter's AC output voltage.
Grid (AC1) Volts AC - Not used.
Generator (AC2) Volts AC - Displays the incoming line voltage
from either shore power or generator to the inverter.
Read Frequency Hertz - Displays the number of cycles per
second of incoming power to the inverter.
This section covers the procedure to program the automatic generator start
function. There are several variables to the program. Some settings may work
fine in one location, but not in another. The order of instructions will follow
the sequence of the headings. Read all instructions thoroughly. This is not a
substitute for the inverter manual.
Setting the Clock (24 hour):
1. Using the Menu Headings buttons scroll to menu number "6
Time of Day."
2. Press the DOWN button on the Menu Items button, Set Clock
Hour will display. Use the Set Point buttons to set the hour. Time
changes in ten minute increments. The clock is a 24 hour clock.
For example: 9:00 a.m. would be 09:00, 3 p.m. would be 15:00
and 7 p.m. would be 19:00.
3. Press the DOWN button on the Menu Items button, "Set Clock
Minute" will display. Use the Set Point buttons to set the minute.
4. Press the DOWN button on the Menu Items button, "Set Clock
Second" will display. Use the Set Point buttons to set the second.
Setting Generator Timer:
5. Press the Menu Headings DOWN button, Menu Heading number
"7 Generator Timer" will display.
6. Press the DOWN button on the Menu Items button, "Start Quiet
Time h:m" will display. Start Quiet Time is the time you want
the generator to stop running or not start at or after quiet time
begins. Using the Set Point buttons to set the hour and minute (24
hour clock) the generator will start quiet time.
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------