Programming & Resetting - Holiday Navigator 2003 Owner's Manual

Table of Contents

Advertisement

Electrical Systems - House
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Programming
& Resetting
8 • 3 0 6
Green Button:
Press the green button to scroll the cursor. An underscore of the first letter
indicates the selected mode. Press the green button to enable the Automatic
Generator Start program, start the generator or begin Equalize Charge.
OFF - Turns off inverter control over any generator function.
AUTO - Enables the automatic generator start program.
ON - Overrides the automatic start program and starts the generator.
EQ - Starts an Equalize Charge to the house batteries on the next start
cycle of the automatic generator start. The equalize charge (EQ) feature
applies a high-voltage charge to the house batteries. The Equalize Charge
voltage can exceed voltage operating limits of engine, transmission or
other sensitive electronic equipment resulting in extensive damage. The
EQ feature should only be enabled by qualified personnel. Before
beginning an equalize charge, consult the battery manufacturer to obtain
information on performing an equalize charge.
WARNING: An Equalize Charge uses a significantly higher than
normal charge voltage. This voltage can damage sensitive electronic
equipment. Several precautionary measures are required when
performing an Equalize Charge. Only qualified motorcoach personnel
should enable this feature. Consult the battery manufacturer before
beginning an equalize charge cycle.
Inverter Reset:
The factory default settings in the inverter are set to optimum values for
most situations. Slight adjustments may be necessary depending on the amperage
available from shore power, personal habits and battery type. A comprehensive
study should be done before making any changes to the programming profile.
If the programming was altered, it is easily reset to the factory default values.
To Reset the Inverter:
• Press the Menu Headings Down button on the remote until Trace
Engineering heading "3" displays.
• Using the Menu Item buttons, scroll down until "Press Reset
Now For Default" displays on the screen.
• Using the eraser end of a pencil or a pen, press the "Reset to
Factory Default" button on the remote.
NOTE: The main switch on the inverter remains ON.