Electrical Systems - House
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
8 • 2 9 0
The programming is now set for Automatic Generator Start. Exit programming
mode by simultaneously pressing the Set-up buttons. Waiting for AC,
Inverting or a charge status Bulk, Absorb or Float should now be displayed
When the generator starts from the Auto Start program it will automatically
stop at 90% state of charge. If the generator started from the Auto Start
program and the inverter has not shutdown by Gen Quiet Time, the inverter
will shut the generator off.
A RED error light flashes and the display will indicate Gen Quiet Time.
The fault alarm will sound for a short time and can be silenced by pushing the
Up or Down button.
NOTE: To start the generator manually after the Automatic
Generator Start feature is enabled, it must be started from the RC7
GS remote. If the generator is started manually from any remote
switch other than the RC7 GS remote while the Automatic
Generator Start feature is enabled, the inverter may shut the generator
off due to the parameters set.
Starting the Generator Manually:
• Use the RC7 GS remote to start or stop the generator when the
Automatic Generator Start feature is enabled.
• Press the UP or DOWN arrow (while in the main menu) until
Generator Start/Stop: Press (ON/OFF) is displayed.
• Press and hold the ON/OFF button until the generator starts. The
display will indicate the generator was started manually. Use the
ON/OFF button or any of the generator start/stop switches to stop
the generator.
To Disable Automatic Generator Operation:
• Set the generator Start and Stop points back to Manual ON/OFF
or switch off the house and chassis main battery disconnects to
erase the clock time and generator start/stop programming.