Set Load Stop Delays Min - This is the time period the generator
continues to operate after the generator started from the setting in the Set
Load Start amps AC menu item.
Set 24 hr Start Volts DC - Starts the generator if the voltage drops below
the setting for a consecutive 24 hour period. For example: If the voltage is set
for 12.5 Volts DC and house battery voltage drops below 12.5 Volts for a
continuous 24 hour period the generator will start. This setting is helpful when
storing the motorhome.
CAUTION: It could be several days before the generator
starts from the 24 hour voltage setting. Do not use this setting
when storing the motorhome inside a storage building. Do
not park the motorhome near dry grass.
Set 2 hr start Volts DC - Starts the generator if the voltage drops below
the setting for a consecutive two hour period. For example: If the voltage is set
for 12.0 Volts DC and house battery voltage drops below 12.0 Volts for a
continuous two hour period the generator will start. This voltage setting is
usually lower than the 24 hr start voltage setting. Primarily used when dry
camping. An example would be a light load on the house batteries over time.
Voltage drops at relatively steady rate until obtaining the preset voltage for
two continuous hours.
Set 15 min start Volts DC - Same operating principal as the previous two
menu items. This voltage setting is used when applying heavy loads to the
house batteries. An example: Using many lights and the inverter to watch the
television and operating the microwave. These types of loads rapidly deplete
battery reserves. Battery voltage drops quickly when applying heavy loads to
the house batteries.
Read 30 sec LBCO start VDC - Used with the menu item Set Low
Battery Cut Off VDC under menu heading number "9 Inverter Setup." If house
battery voltage drops to this point, the inverter waits 30 seconds before starting
the generator.
NOTE: This start setting overrides quiet time.
NOTE: The generator will operate until the bulk and absorption
cycles are complete if the generator started from one of the
low battery settings.
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
N A V I G A T O R 2 0 0 3
Electrical Systems - House
8 • 3 1 1