Electrical Systems - House
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Re-booting the
Inverter
8 • 3 0 2
To Exit Equalize Charge:
• The equalize charge cycle may be discontinued at any time during
the charge cycle. Press and hold the settings button for six seconds.
The inverter will display System Status: Absorb for thirty seconds
then switch to float charge.
• Allow the batteries to cool for approximately three hours. Check
the electrolyte solution with a hydrometer. Avoid overcharging the
battery resulting in damage to the healthy cells.
• Add distilled water if necessary. Install battery caps. Use large
quantities of fresh water to rinse the entire battery compartment
and surrounding area.
• Install fuses to solar panel charge leads.
• Observing polarity, hook the 12 Volt DC supply leads to the back
of the refrigerator. Do not reverse polarity. Damage to the refrigerator
circuit board can result.
• Hook up the battery maintainer. Be sure the wires are connected to
the correct location.
CAUTION: Never equalize charge a frozen battery.
WARNING: Liquid lead acid batteries produce highly explosive
hydrogen gas when being charged. Extinguish all flames and other
sources of ignition. Never smoke around batteries. Danger of
explosion, fire, property damage, serious personal injury or death
can result!
The remote is used to program or turn on or off the inverter. The RC7 GS
remote is a display only. All the programming information is retained in the
inverter. If the inverter exhibits unusual symptoms, such as not responding to
commands or displaying erroneous error conditions, re-booting the inverter
may alleviate these symptoms.
To Re-boot the Inverter:
1. Remove AC power from the inverter by disconnecting shore power
and/or shutting the generator off.
2. Turn the main switch on the inverter to the OFF position.
3. Switch house and chassis main battery disconnects to the OFF position.
4. Wait 30 seconds, this allows time for capacitors to discharge.
5. Switch house and chassis main battery disconnects to the ON position.
6. Turn the main switch on the inverter to the ON position.
7. Connect the shore power cord or start the generator.