NOTE!
The third and fourth digit of the serial number provide information on the year of pro-
duction. Example: Serial number „S310045208" corresponds to production year
2010.
9.6

Mode of operation module replacement

BM5-O-SAF-100 (Reset-Module)
Switch on
Writing of module identifications:
Module version (P200.001 := 1)
Firmware version module (P200.002)
Hardware version module (P200.003)
Serial number (P200.004)
Deleting of
safe parameter file
and of protocol file
of b maXX 5000
No error
Command processing
Figure 23:
Mode of operation module replacement BM5-O-SAF-100
Operation Manual Safety Module for b maXX 5000 BM5-O-SAF-000/-001
Description of the Reset-Module
b maXX 5000 (Regler)
Sc
an for 5 s,
meanwhile
no
display
of
m
odule version
Sc
an to BM5-O-SAF-100
(P200.001 == 1)
Switch on
BM5-O-SAF-100
available
Reset
last module version
(P200.008 := 0)
Error
message
(error number 2423)
D
rive state:
Failure
(P108.006 = 15)
Command processing
Document no.: 5.09013.07
9
63