Saf-001-001-Xxx - Baumuller BM5-O-SAF-000 Operating Instructions Manual

Safety module for b maxx 5000
Table of Contents

Advertisement

5.1.2

SAF-001-001-xxx

The values in the following table relate exclusively to the Safety Module (BM5-O-SAF-
001-001-xxx) per axis.
m Parameters in accordance with IEC 61508-1 to 7 and IEC 62061
m Parameters in accordance with EN ISO 13849-1
Operation Manual Safety Module for b maXX 5000 BM5-O-SAF-000/-001
(Data if the device is used as part of a safety function)
n SIL CL 3
n PFH:
3,6 x 10
n PFD
:
3,2 x 10
av
n Proof test interval
Note:
If the PFH value is less than 1% of the allowed SIL level, the execution of a
special proof test is not considered to be necessary within the operating time
of the device.
n Performance Level
n Category:
n MTTF
:
D
n Diagnostic Coverage DC:
Functional safety
-10
1/h,
according to 0,4 % of SIL 3
-5
according to 3,2 % of SIL 3
20 years
PL e
Kat 4
HIGH (751 a)
HIGH (99 %)
Document no.: 5.09013.07
5
27
of 114

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bm5-o-saf-001