Baumuller b maXX BM4 Series Instruction Handbook Manual
Baumuller b maXX BM4 Series Instruction Handbook Manual

Baumuller b maXX BM4 Series Instruction Handbook Manual

Analog io module
Table of Contents

Advertisement

Instruction handbook
English
Language
Translation
Document No. 5.01045.08
Part No.
372665
Status
12-Dec-2014
E
5.01045.08
Read the Manual before starting any work!
b maXX
BM4-F-AIO-XX
AIO-XX
Analog IO module
BM4400, BM4400 ES
BM4600, BM4600 ES
BM4700, BM4700 ES

Advertisement

Table of Contents
loading

Summary of Contents for Baumuller b maXX BM4 Series

  • Page 1 Instruction handbook English Language Translation Document No. 5.01045.08 Part No. 372665 Status 12-Dec-2014 b maXX BM4-F-AIO-XX AIO-XX Analog IO module BM4400, BM4400 ES BM4600, BM4600 ES BM4700, BM4700 ES Read the Manual before starting any work! 5.01045.08...
  • Page 2 Copyright This Instruction handbook may be copied by the owner in any quantity, but only for internal use. This Instruction handbook may not be copied or reproduced, in whole or in part, for any other purposes. The use and disclosure of information contained in this Instruction handbook are not permit- ted.
  • Page 3: Table Of Contents

    Table of contents General ..............Information on this Instruction handbook .
  • Page 4 Table of contents Mounting ..............33 Preparation of mounting .
  • Page 5: General

    ENERAL Information on this Instruction handbook The AIO-XX or BM4-F-AIO-XX can be operated in combination with a b maXX 4000, only. Therefore this Instruction handbook is an addition to the Instruction handbook of b maXX BM4400, BM4400 ES, BM4600, BM4600 ES, BM4700, BM4700 ES (short b maXX 4000) 5.12008.
  • Page 6: Key To Symbols

    Key to symbols Key to symbols Warning notes Warning notes are identified by symbols in this Instruction handbook. The notes are in- troduced by signal words that express the extent of the danger. It is imperative that these notes be complied with and are conscientiously regarded in or- der to prevent accidents, personal injury and material damage.
  • Page 7: Limitation Of Liability

    General Limitation of liability All specifications and notes in these instruction handbook were compiled taking into ac- count the applicable standards and regulations, the state of the art and our knowledge and experience of many years. The manufacturer assumes no liability for damages due to: m noncompliance with the instruction handbook m usage for other than the intended purpose m usage by untrained personnel...
  • Page 8: Other Applicable Documents

    Other applicable documents Other applicable documents Components of other manufacturers are integrated into the device. For these purchased parts, hazard assessments have been performed by the respective manufacturers. The compliance of the design construction with the applicable European and national regula- tions has been declared for the components by the respective manufacturers.
  • Page 9: 1.10 Used Terms

    General 1.10 Used terms The term function module or the designation AIO-XX (ES controller) or BM4-F-AIO-XX (standard controller) is also used in this documentation for the Baumüller product „b maXX analog IO module“. A list of the abbreviations used can be found in b maXX 4000 5.12008, Appendix A: Abbreviations.
  • Page 10 1.11 List of associated documentations Doc No. Part No. Part No. German English SERCOS slave module BM4-O-SER-01 5.04012 380910 381069 SERCOS slave module BM4-O-SER-01 parameter handbook 5.04013 381652 381653 EtherCAT slave module BM4-O-ECT-01/ECT-01 5.06003 394953 394954 Ethernet with EtherCAT master for b maXX drive PLC 5.07001 407996 407997...
  • Page 11: Safety

    AFETY This section provides an overview of all of the important safety aspects for optimum pro- tection of personnel as well as for the safe and problem-free operation. Contents of the Instruction Handbook Each person who is tasked with performing work on or with the device must have read and understood this Instruction Handbook and the Instruction Handbook of b maXX 4000 5.12008 before working with the device.
  • Page 12: Use, Compliant With Intended Purpose

    Use, compliant with intended purpose Use, compliant with intended purpose The BM4-F-AIO-XX is used compliant with its intended purpose, if it is built-in/operated within b maXX 4000 controller, only. The Analog IO module is considered as being used compliant with its intended purpose if all notes and information of this Instruction handbook and the Instruction handbook b maXX 4000 5.12008 are adhered to.
  • Page 13: Training Of The Personnel

    Safety Training of the personnel WARNING! Risk of injury due to insufficient qualifications! Improper handling can lead to significant personal injury and material damage. Therefore: m Certain activities can only be performed by the persons stated in the respective chapters of this Instruction handbook. In this Instruction handbook, the following qualifications are stipulated for various areas of activity: m Operating personnel...
  • Page 14: Special Hazards

    Special hazards Special hazards In the following section, the remaining marginal risks will be stated that have been iden- tified as a result of the hazard analysis. Observe the safety notes listed here and the warning notes in the further chapters of this manual to reduce health risks and dangerous situations.
  • Page 15: Fire Fighting

    Safety Moving components WARNING! Risk of injury from moving components! Rotating components and/or components moving linearly can result in severe injury. Therefore: m Do not touch moving components during operation. m Do not open any covering during operation. m The amount of residual mechanical energy depends on the application. Powered components still turn/move for a certain length of time even after the power supply has been switched off.
  • Page 16: Safety Equipment

    Safety equipment Safety equipment WARNING! Risk of fatal injury due to non-functional safety equipment! Safety equipment provides for the highest level of safety in a facility. Even if safety equipment makes work processes more awkward, under no circumstances may they be circumvented.
  • Page 17: 2.10 Signs And Labels

    Safety 2.10 Signs and labels The following symbols and information signs are located in the working area. They refer to the immediate vicinity in which they are affixed. WARNING! Risk of injury due to illegible symbols! Over the course of time, stickers and symbols on the device can become dirty or oth- erwise unrecognizable.
  • Page 18 2.10 Signs and labels Instruction handbook b maXX (BM4-F-)AIO-XX (Analog IO module) Document No.: 5.01045.08 Baumüller Nürnberg GmbH of 82...
  • Page 19: Technical Data

    ECHNICAL Electrical data (BM4-F-)AIO- Number of inputs Number of IO-input links Resolution 10 bit / 12 bit 16 bit 12 bit 16 bit Design differential input circuit ca. 100 Ω Input resistance ca. 50 kΩ Max. input current 200 µA 20 mA Min.
  • Page 20: Power Input

    Power input Power input (BM4-F-)AIO- up to (BM4-F-)AIO-03-00 from (BM4-F-)AIO-03-01 Voltage version C* version D* 5,0 V 0,2 mA 4 mA 10 mA 5 mA 4 mA 3,3 V 160 mA 40 mA +15,0 V 27 mA 37 mA 20 mA 23 mA 37 mA -15,0 V...
  • Page 21: Design And Operation

    ESIGN AND PERATION A b maXX BM4000 device consists of power unit and controller part Power unit Controller part standard controller Design cover (standard controller only) Standard controller BM4XXX-XXX-XX1XX BM4XXX-XXX-XX2XX BM4XXX-XXX-XX3XX Controller part ES controller ES controller BM4XXX-XXX-XX4XX BM4XXX-XXX-XX5XX Figure 1: b maXX BM4000) The BM4-F-AIO-XX is designed as plug-in module within the standard controller and can be replaced or upgraded.
  • Page 22: Function

    Function Function The Analog IO module converts analog input signals in digital signals for control (e.g set value generation) and/or makes available converted analog values (e. g. for RPM dis- play) from internally processed digital signals. ZTechnical Data– Technical data of the Analog IO module can be found in from page NOTE! The operation with ProDrive is described, only.
  • Page 23: Bm-F-Aio-Xx For Standard Controller

    Design and Operation BM-F-AIO-XX for standard controller The BM4-F-AIO-XX is a plug-in module for the controller of b maXX 4000-series. The BM4-F-AIO-XX plug-in module is connected to the controller with a plug on its back. On the front is a 9-pin Sub-D connector (male). Plug (back side) Module identification AIO-01...
  • Page 24 BM-F-AIO-XX for standard controller Optional plug-in modules (function or option modules) can be upgraded dependent on the existing controller type. Possible combinations function modules/option modules Function modules Option modules Controller unit preferred slot Baumüller Nürnberg GmbH recommends, in order to reach the highest functional range, to insert the plug-in modules into these slots.
  • Page 25: Type Plate Bm4-F-Aio-Xx For Standard Controller

    Design and Operation NOTE! Only 2 analog outputs can be parametrized or linked even more than one AIO module is plugged. NOTE! EtherCAT option modules must not be plugged in slot J of a 3-rowed controller unit, because the module can be damaged. In case another BM4X-X-XXX plug-in module is plugged in an unsuitable slot, it will not operate.
  • Page 26: Type Code Bm4-F-Aio-Xx For Standard Controller

    BM-F-AIO-XX for standard controller 4.2.3 Type code BM4-F-AIO-XX for standard controller NOTE! This type code is valid for the BM4-F-AIO-XX of series b maXX 4000 exclusively. For other plug-in modules different type codes are available. Type code: AIO - XX - YY Device family, in which the plug-in module can be built in - F - AIO - XX - YY...
  • Page 27: Aio-Xx In Es Controller

    Design and Operation AIO-XX in ES controller The AIO-XX is mounted stationary in the ES controller. e.g. AIO-02 position C AIO-01 always position E Figure 4: AIO-XX for ES controller The controller is ordered with the desired function/option modules, these are mounted stationary (exception slot H) and cannot be changed.
  • Page 28: Position Aio-Xx In Es Controller

    AIO-XX in ES controller 4.3.1 Position AIO-XX in ES controller Each position is clearly identified by a character. The AIO-XX can be used at the following position. AIO-02 AIO-03 AIO-04 AIO-01 Controller Combinations function modules/option modules Function modules Option modules Controller unit with RS232- or Ethernet interface prefered slot Steckkarten_ES_Rev02_e...
  • Page 29: Type Plate Aio-Xx In Es Controller

    Design and Operation NOTE! Only 2 analog outputs can be parametrized or linked even more than one AIO module is available. 4.3.2 Type plate AIO-XX in ES controller The type code of the AIO-XX is included in the type plate of the basic unit. 4.3.3 Type code AIO-XX in ES controller The type code has the form:...
  • Page 30 Display and operation elements Instruction handbook b maXX (BM4-F-)AIO-XX (Analog IO module) Document No.: 5.01045.08 Baumüller Nürnberg GmbH of 82...
  • Page 31: Transport And Packaging

    RANSPORT AND ACKAGING What to observe when transporting For initial transport the BM4-F-AIO-XX for standard controller is packed at the manufac- turer. If the device is to be further transported, ensure that the following conditions are met throughout the entire transport: m Climate class 2 K 3 as per EN 60721-3-2 m Temperature range - 30 °C up to + 70 °C m Vibration, shock, continuous shock class 2 M 1 as in EN 60721-3-2...
  • Page 32: Unpacking

    Unpacking Unpacking After having received the still packaged device: h Avoid transport shocks and hard jolts, e.g. when putting an item down. If no transport damage is visible: h Open the packaging of the device. h Verify the delivery scope based on the delivery note. File a claim with the responsible Baumüller representative if the delivery is incomplete.
  • Page 33: Mounting

    OUNTING In this chapter we describe the mechanical mounting of the plug-in module BM4-F-AIO-XX for BM4400, BM4600, BM4700 with standard controller. NOTE! The AIO-XX modules are mounted stationary in the BM4400, BM4600, BM4700 with ES controller and cannot be changed, therefore no mounting is necessary! Preparation of mounting h Check the marking AIO-XX, whether the right plug-in module is available.
  • Page 34: Assembly

    Assembly Assembly WARNING! Danger as a result of faulty mounting! The mounting requires qualified personnel with adequate experience. Faulty mount- ing can lead to life-threatening situations or substantial material damage. Therefore: m Only allow mounting to be performed by employees of the manufacturer or by oth- er qualified personnel.
  • Page 35 Mounting 4 Turn the twist lock beyond and beneath by 90°. The twist locks now are standing horizontally. 5 Take the front panel cover towards the front off. Keep this cover. NOTICE! Note electrostatic discharge! The BM4-F-AIO-XX contains ESD sensible parts. Therefore: m Regard the described ESD procedures when handling the plug-in module.
  • Page 36 Assembly Instruction handbook b maXX (BM4-F-)AIO-XX (Analog IO module) Document No.: 5.01045.08 Baumüller Nürnberg GmbH of 82...
  • Page 37: Installation

    NSTALLATION In this chapter we describe the electrical installation of the AIO-XX or BM4-F-AIO-XX. ZMounting– The mechanical mounting is described in from page 33 and not necessary for BM4400, BM4600 and BM4700 with ES controller. Safety notes DANGER! Risk of fatal injury from electrical current! There is an immediate risk of fatal injury if live electrical parts are contacted.
  • Page 38: Requirements On The Electrical Connection

    Requirements on the electrical connection Requirements on the electrical connection NOTICE! The danger is: Electricity. In case you do not ensure the requirements to the electrical connection of the Analog IO module, it can be damaged/destroyed. m Ensure that the electrical power connection parameters as specified in the techni- cal data are adhered to and that the connections are made in accordance with the instructions.
  • Page 39: Connection Diagrams

    Installation Connection diagrams Standard controller ES controller Figure 7: Connection diagram Analog IO module Pin assignment Pin No. Assignment IN 1 + IN 2 + OUT 1 - , OUT 2 - OUT 1 + OUT 2 + IN 1 - IN 2 - OUT 1 - , OUT 2 - OUT 1 - , OUT 2 -...
  • Page 40: Installation Procedure

    Installation procedure Installation procedure 1 Switch off the b maXX 4400 device and assure it against unintentional switching on during mounting. DANGER! Risk of fatal injury from electrical current! There is an immediate risk of fatal injury if live electrical parts are contacted. Therefore: m Switch off the current when any kind of work is being performed on the electrical system and ensure safety before switching on again.
  • Page 41: Internal Circuit Diagram

    Installation Internal circuit diagram 7.6.1 Internal circuit diagram of Analog-IO-Modules (BM4-F-)AIO-01/-02/-03 Figure 8: Internal circuit of Analog IO module (BM4-F-)AIO-01/-02/-03 Instruction handbook b maXX (BM4-F-)AIO-XX (Analog IO module) Document No.: 5.01045.08 of 82...
  • Page 42: Internal Circuit Diagram Of Analog Io Module (Bm4-F-)Aio-04

    Internal circuit diagram 7.6.2 Internal circuit diagram of Analog IO module (BM4-F-)AIO-04 Figure 9: Internal circuit diagram of Analog IO module (BM4-F-)AIO-04 Instruction handbook b maXX (BM4-F-)AIO-XX (Analog IO module) Document No.: 5.01045.08 Baumüller Nürnberg GmbH of 82...
  • Page 43: Commissioning/Operation

    OMMISSIONING PERATION This commissioning assures, that the Analog IO module has been correctly recognized. Further information relating to commissioning and parameter settings of the encoder module can be found in parameter manual b maXX 4000 5.03039. Assure that before commissioning the following preconditions are fulfilled: 1 The BM4-F-AIO-XX is correctly mounted (standard controller only).
  • Page 44: Procedure Of The Commissioning

    Procedure of the commissioning NOTICE! Environmental conditions that do not meet the requirements. Environmental conditions that are non-compliant can lead to property damage. Therefore: m Ensure that the environmental conditions are kept compliant during operation (see instruction handbook b maXX 4000, operation conditions). WARNING! Risk of injury due to insufficient qualifications! Inevitably, when operating this electrical device, certain parts of this device are ener-...
  • Page 45: Prodrive Navigation

    Commissioning/Operation 3 Open with ProDrive the window „Diagnosis“. Figure 10: ProDrive navigation Instruction handbook b maXX (BM4-F-)AIO-XX (Analog IO module) Document No.: 5.01045.08 of 82...
  • Page 46: Prodrive Service

    Procedure of the commissioning 4 Choose submenu „Service“ This window shows the position/slot of the recognized Analog IO module. If the Analog IO module is available in position/slot D, then the following is displayed: „Slot D Analog IO 16 Bit Version X“. „X“...
  • Page 47: Prodrive Navigation, Submenu „Io Analog Inputs

    Commissioning/Operation 6 Icon „ProDrive Navigation“ 7 Configuration / submenu „IO analog inputs“ Figure 12: ProDrive navigation, submenu „IO analog inputs“ 8 The submenu contains „Analog input link 1 and 2“ e.g. choose „Analog input link 1“ The window „Analog input link 1“ is opened. The inputs can be selected in the center of the window.
  • Page 48: Analog Input Link

    Procedure of the commissioning 9 Choose „Input D.1“ in drop down list if the Analog IO module is used in position/slot D. Figure 13: Analog input link 1 10 Check whether the text: „module not existent“ is displayed directly under the scale. In this case, the module was not recognized.
  • Page 49: Testing Of The Analog Io Module

    Commissioning/Operation NOTICE! Notice electrostatic discharge The BM4-F-AIO-XX or the b maXX BM4000 may get damaged if the module is plugged or pulled out when the b maXX BM4000 is energized. If the plug-in module has still to be pulled out from the b maXX BM4000 due to an external action, switch off the b maXX BM4000.
  • Page 50: Testing Of Inputs Aio-01, -02 And -03

    Procedure of the commissioning 8.2.2.1 Testing of inputs AIO-01, -02 and -03 1 ProDrive Navigation „IO analog inputs“. 2 Select „Analog input link 1“ in ProDrive. Figure 15: Analog input link 1, AIO-01, -02 and -03 -symbol, select the entry „Input D.1“ („D“ ⇒ module in position D, 3 By clicking on the „1“...
  • Page 51: Testing Of Inputs Aio-04

    Commissioning/Operation 5 Check the display in „Analog input link 1“. The RPM of the motor can be regulated now by potentiometer for instance within limits -10 V and +10 V (clockwise and counter-clockwise running). NOTE! If for example, the scale shows 0 V, even though there is an analog voltage applied ZConnection diagrams–...
  • Page 52: Input Selection Aio-04

    Procedure of the commissioning -symbol, select the entry „Input E.1“ („E“ ⇒ module in position E, 3 By clicking on the „1“ ⇒ input 1) from the drop-down list. Figure 18: Input selection AIO-04 4 Enter in menu „Analog input link 1“ : m Target parameter number: „1171“, (ramp function generator input) m Smoothing time: „10 ms“, m Scaling factor: „1“,...
  • Page 53: 8.2.2.3 Testing Of Outputs

    Commissioning/Operation 8.2.2.3 Testing of outputs ZPre-conditions– Note the on page 49. 1 Select in ProDrive „IO analog outputs“ Figure 19: Analog output link 2 Select submenu „Analog output link 1“. Figure 20: Menu Analog output link 1 Instruction handbook b maXX (BM4-F-)AIO-XX (Analog IO module) Document No.: 5.01045.08 of 82...
  • Page 54: Output Selection

    Procedure of the commissioning -symbol, select the entry „Output D.1“ („D“ ⇒ Analog IO module 3 By clicking on the in position D, „1“ ⇒ output 1) from the drop-down list. Figure 21: Output selection 4 Enter in menu Analog output link 1: m Source parameter: „1171“, m Offset: „0 dig“, m Shift factor: „0“,...
  • Page 55: Offset Adjustment Of An Analog Input Channel

    Commissioning/Operation 8.2.3 Offset adjustment of an analog input channel Pre-conditions Basic unit b maXX BM4000 commissioning completed, Analog IO module available. 8.2.3.1 Offset adjustment of AIO-01, -02, -03 n Voltmeter Required accessory n Voltage source (e.g. 9V monobloc battery) with Sub-D connector (9 pin) for analog inputs 1 and 2 and connection for the voltmeter n Sub-D connector (9 pin) with inputs 1 and 2 short-circuited ZConnection diagrams–...
  • Page 56 Procedure of the commissioning Gain adjustment within the analog input link Connection and measurement of a reference voltage (e.g. 9V monobloc battery) Measured voltage (voltmeter): 9,235 V Read value in ProDrive: 29295 ⋅ read value 10 V Conversion of read value into voltage: = ---------------------------------------------- 32767 ⋅...
  • Page 57: Offset Adjustment Aio-04

    Commissioning/Operation 8.2.3.2 Offset adjustment AIO-04 n Current calibrator Required accessory n Computer with ProDrive n Amperemeter NOTE! All settings must be done when controller state is disabled. Offset adjustment within the analog input link Set 16 Bit application parameter as target for the analog input link. Example: Target parameter = P3333 Read the value in ProDrive while input is open (0 mA).
  • Page 58: Operation

    Operation Operation Setting of parameters determines the reaction of the Analog IO module during operation. These parameters are set by the software ProDrive. The procedure for “Analog input Link 1” is described below via an example. The proce- dure for “Analog output Link 2” and the analog outputs is similar. 1 Start ProDrive 2 Click „ProDrive Navigation“...
  • Page 59: Configuration, Parameter List

    Commissioning/Operation 6 Click on for opening the parameter list. 7 Click on the -symbol before „Configuration IO analog“ in the window „Parameter- list“. The corresponding parameters of the Analog IO module are displayed. Figure 23: Configuration, parameter list NOTE! ZError The error parameters of the Analog-IO-Modules can be found in the chapter messages–...
  • Page 60 Operation Instruction handbook b maXX (BM4-F-)AIO-XX (Analog IO module) Document No.: 5.01045.08 Baumüller Nürnberg GmbH of 82...
  • Page 61: Maintenance

    AINTENANCE Safety notes Basic information WARNING! Risk of injury due to improperly performed maintenance work! Improper maintenance can lead to severe personal injury and material damage. Therefore: m Before beginning work, make sure that there is enough space for mounting. m Make sure that the mounting area is kept clean and orderly.
  • Page 62: Inspection Intervals - Maintenance Notes

    Inspection intervals - maintenance notes Inspection intervals - maintenance notes Refer to Instruction handbook b maXX 4000, 5.12008. Repairs In case of device damage, please inform your sales office or: Baumüller Nürnberg GmbH Ostendstr. 80 - 90 90482 Nuremberg Germany Tel.
  • Page 63: Troubleshooting And Fault Correction

    ROUBLESHOOTING AND AULT CORRECTION 10.1 Behavior in case of malfunctions Basic information DANGER! Risk of fatal injury from electrical current! Inevitably, when operating this electrical device, certain parts of it are energized with hazardous voltage. Therefore: m Pay heed to areas on the device that could be dangerous. WARNING! Risk of injury due to improper fault correction! Therefore:...
  • Page 64: Fault Detection

    10.2 Fault detection 10.2 Fault detection The fault can be caused by mechanical or electrical malfunctions. LED H4 The occurrence of an error state of a device b maXX 4000 is signalled by the lighting up of the red LED H4 on the front side of the housing. NOTE! If warnings or errors occur without error reaction the LED H4 „error“...
  • Page 65 Troubleshooting and Fault correction Operating Furthermore the error message is shown in the operating software: software ProDrive h Start the operating program ProDrive (from FW 3.07), if it isn’t running yet. NOTE! The controller software version and the operating software version must be compat- ible to use ProDrive with all functions.
  • Page 66: Drive Manager Prodrive

    10.2 Fault detection h Select „Drive management“ The window „Drive manager“ opens, see below with an exemplary (error) message. Before the communication between controller and PC/laptop is started, the messages in this list have been arranged in numerical order. The newly occurring messages are added to the end of the list, when communication is active.
  • Page 67: 10.3 Error Handling

    Troubleshooting and Fault correction 10.3 Error handling The error messages in the system are built up hierarchically. An error message can result from a beneath in the hierarchic arranged error message. This is why the message „Error“ (level 1) can base on an error, which e. g. has appeared in „ModuleError“...
  • Page 68: 10.3.1 Error Reset

    10.3 Error handling 10.3.1 Error reset If the red error LED is lighting up, there is at least one error. There are several methods to reset errors: m Via ProDrive (from FW 3.07): Button “Quit errors” (either in the dialog box “Device manager” or on the page “Device manager“.
  • Page 69: 10.3.2 Error Messages

    Troubleshooting and Fault correction 10.3.2 Error messages Figure 28: Survey error list The (error) messages are displayed in ProDrive window „Drive manager“. Instruction handbook b maXX (BM4-F-)AIO-XX (Analog IO module) Document No.: 5.01045.08 of 82...
  • Page 70 10.3 Error handling 1st level 1st level errors are only interesting for the access to errors via parameters, to be used without ProDrive, e. g. at Field bus communication. These errors are not shown in Pro- Drive/7-segment display. Bit mapping see description of the parameter P0200 in the parameter manual. 2nd level Order of the error messages see survey (ZAbbildung 28–...
  • Page 71 Troubleshooting and Fault correction 3rd level error messages NOTE! 3rd level errors are only displayed in ProDrive separated by a decimal point from the ZAbbildung 28– corresponding 2nd level error (refer to auf Seite 69). e.g.: Motor error 102: Group error find notch position (2nd level) Find notch position error 102.64: Drive moved more than 4 times delta angle.
  • Page 72 10.3 Error handling Instruction handbook b maXX (BM4-F-)AIO-XX (Analog IO module) Document No.: 5.01045.08 Baumüller Nürnberg GmbH of 82...
  • Page 73: Disposal

    ISPOSAL NOTE! Baumüller products are not subject to the scope of application of the EU's Waste Electrical and Electronic Equipment Directive (WEEE, 2002/96/EC). Hence, Baumüller is not obligated to bear any costs for taking back and disposing of old de- vices.
  • Page 74: Disposal Facilities/Authorities

    11.2 Disposal facilities/authorities NOTICE! Avoid polluting the environment as a result of improper disposal. Therefore: m Only dispose in compliance with the health and safety regulations. m Take heed of any special local regulations. If you are unable to directly ensure safe disposal yourself, commission a suitable disposal contractor.
  • Page 75: Appendixa - Declaration Of Conformity

    A - D PPENDIX ECLARATION OF ONFORMITY Instruction handbook b maXX (BM4-F-)AIO-XX (Analog IO module) Document No.: 5.01045.08 of 82...
  • Page 76 EG - Declaration of Conformity Doc.-No: 5.12050.00 Date: 25-Sep-2012 according to EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC The Manufacturer: Baumüller Nürnberg GmbH Ostendstraße 80-90 90482 Nuremberg, Deutschland declares that the product: Name: b maXX Type: Analog IO module b maXX BM4000 BM4-F-AIO-01, BM4-F-AIO-02, BM4-F-AIO-03, BM4-F-AIO-04 From manufacturing date: 1-Oct-2012 as developed, designed and manufactured in accordance with the EMC Directive 2004/108/EC and the Low Voltage Di-...
  • Page 77: Table Of Figures

    Table of figures Table of figures b maXX BM4000) ........................Analog IO module for standard controller .................. Type plate BM4-F-AIO-XX for standard controller..............AIO-XX for ES controller ......................BM4-F-AIO-XX for standard controller ..................Mounting ............................ Connection diagram Analog IO module ..................Internal circuit of Analog IO module (BM4-F-)AIO-01/-02/-03............
  • Page 78 Table of figures Instruction handbook b maXX (BM4-F-)AIO-XX (Analog IO module) Document No.: 5.01045.08 Baumüller Nürnberg GmbH of 82...
  • Page 79: Index

    Index Accidents Key to symbols Assembly LED H2 Caution LED H4 Connecting cables, requirements Limitation of liability Customer service Maintenance Danger Malfunctions, behavior Danger areas Modifications DC link discharge time 14, 73 Design cover Note Diagnosis Discharge, electrostatic Disposal 8, 73 Operating instructions, contents Drive management Operating personnel...
  • Page 80 Index Technical data Temperature range Testing of inputs 50, 51 Transport inspection Troubleshooting Twist lock Type code ES controller Standard controller Type of plug-in module Type plate ES controller Standard controller Unpacking Use, compliant with indented purpose Warning Warning notes Instruction handbook b maXX (BM4-F-)AIO-XX (Analog IO module) Document No.: 5.01045.08 Baumüller Nürnberg GmbH...
  • Page 81: Overview Of Revisions

    Revisionsübersicht Overview of Revisions Version Status Changes 5.01045.06 25.09.2012 Revision because of AIO-04, new design 5.01045.07 13.03.2014 Revision ES controller, troubleshooting 5.01045.08 12.12.2014 Troubleshooting Instruction handbook b maXX (BM4-F-)AIO-XX (Analog IO module) Document No.: 5.01045.08 of 82...
  • Page 82 Notes Instruction handbook b maXX (BM4-F-)AIO-XX (Analog IO module) Document No.: 5.01045.08 Baumüller Nürnberg GmbH of 82...
  • Page 84 Baumüller Nürnberg GmbH Ostendstraße 80-90 90482 Nürnberg T: +49(0)911-5432-0 F: +49(0)911-5432-130 www.baumueller.de All information given in this manual is customer information, subject to change without notice. We reserve the right to futher develop and actualize our products continuously using our permanent revision service. Please notice, that specifications/data/information are current values according to the printing date. These statements are not legally binding according to the measurement, computation and calculations.

Table of Contents