Operation And Display Elements; Leds For Indicating The Operation Statuses - Baumuller BM5-O-SAF-000 Operating Instructions Manual

Safety module for b maxx 5000
Table of Contents

Advertisement

8.11

Operation and display elements

8.11 Operation and display elements

8.11.1 LEDs for indicating the operation statuses

There are two LEDs (LED H1 - green, LED H2 - red) on the front of the Safety
Module (SAF-001-000-xxx) that indicate the current operation status.
m LED H1 (green) - Indicates the trouble-free operation
m LED H2 (red) - Indicates failures or incompatibility with the converter
LED H1 - green
LED H2 - red
Figure 16:
The following table lists the possible combinations of the status LEDs and the
corresponding meaning:
The Safety Module (SAF-001-001-xxx) has no LEDs.
54
Operation Manual Safety Module for b maXX 5000 BM5-O-SAF-000/-001
Document no.: 5.09013.07
of 114
LEDs on front of the Safety Module (SAF-001-000-xxx)
LED
H1 (green)
H2 (red)
Off
Off
On
Off
Off
Flashes
Off
On
S1
H1
H2
X1
No supply voltage.
Trouble-free operation.
Device error or unallowed replacement of the module
(commissioning not possible).
Firmware and parameter data of the Safety
Module (SAF-001) do not correspond with the data of
the converter. The parameter data of the converter has
to be copied to the Safety Module (SAF-001) by
pressing the button S1 (long - short - short - long).
Type plate
Meaning
Baumüller Nürnberg GmbH