Electric Safety; Notice On Power Supply; Safety Equipment - Baumuller BM5-O-SAF-000 Operating Instructions Manual

Safety module for b maxx 5000
Table of Contents

Advertisement

4.10 Electric safety

The plug-in module is designed for contamination level 2 in accordance with
DIN EN 61800-5-1. This means that only non-conductive contamination may appear
during operating time. Short-term conductivity from condensation is only permissible if the
module is not in operation.
WARNING!
Risk of injury from conductive contaminants!
No conductive contaminants may appear during operating time.
Therefore:
m Before installing the system, check that contamination degree 2 is not exceeded,

4.10.1 Notice on power supply

WARNING!
Risk of injury from electric current!
Only devices which have a safe disconnection to the 230 volt mains may be
connected to the plug-in module.
The power supply unit for generating the 24 Volt supply must meet the requirements
for PELV in accordance with EN 60204-1.

4.11 Safety equipment

WARNING!
Live-threatening danger from inoperable safety equipment!
Safety equipment provides a maximum of safety during operation. Even if the safety
equipment may make work processes more complicated, they may not be put out of
operation under any circumstances. Safety is only ensured if the safety equipment is
intact.
Therefore:
m Check to make sure that the safety equipment is functional and installed properly
Operation Manual Safety Module for b maXX 5000 BM5-O-SAF-000/-001
and ensure so by additional measures, if necessary.
before beginning work.
Safety
Document no.: 5.09013.07
4
23
of 114