Setting Of The Switch-On Behavior - Baumuller BM5-O-SAF-000 Operating Instructions Manual

Safety module for b maxx 5000
Table of Contents

Advertisement

7.4

Setting of the switch-on behavior

The switch-on behavior of the SAF-000 parameter module from a b maXX 5000 axis unit
can be set by ProDrive at the page „Data set management" by means of the checkbox
„Load automatical".
Two switch-on behaviors can be set:
The setting „OFF" is usually used during the commissioning of the axis unit. Here it is of-
ten not necessary to backup the parameter data while changes happen. If the commis-
sioning is done, the setting „ON" can be done at the device.
In this setting the SAF-000 parameter module checks at every re-start whether there is a
difference between the parameters of the axis unit and the saved data of the module. If
the data differs, the parameters saved at the SAF-000 parameter module are transmitted
to the axis unit automatically and stored to the flash of the axis unit. At the next re-start
both parameter sets are equal, that means no new transmission has to be done.
This behavior assures, that the parameters are only in the case of service written back
from the module to the axis unit.
Operation Manual Safety Module for b maXX 5000 BM5-O-SAF-000/-001
Description of the Default and Parameter Module
„Load automatical"
OFF
ON
Description
The parameters are not loaded automatically.
The parameters are loaded from the parameter
module at every re-start (Default setting).