Description of the Safety Module (SAF-001)
Wiring of the restart inputs
STO Module
BM5-O-SAF-001
Internal
connections
Internal
connections
Figure 19:
Wiring of restart inhibit inputs axis 1
NOTE!
The restart inputs of the Safety Module (SAF-001) must remain activated after the
restart, i.e., after the activation of the driver supply. The cancellation of the activated
status („on") leads to the deactivation of the driver supply.
DANGER!
The restart inputs may in no case be used for the safety-related shut down of the
driver supply. A safe activation of the safety function STO is only permitted by the
STO inputs and the connected safety components.
Operation Manual Safety Module for b maXX 5000 BM5-O-SAF-000/-001
Restart inhibit
STO_1A_GND (X1-01)
STO_1B_GND (X1-02)
FS_1_GND (X1-03)
STO_2A_GND (X1-04)
STO_2B_GND (X1-05)
FS_2_GND (X1-06)
STO_2A_24V (X1-07)
STO_1A_24V (X1-08)
STO_1B_24V (X1-09)
FS_1_24V (X1-10)
STO_2A_24V (X1-11)
STO_2B_24V (X1-12)
FS_2_24V (X1-13)
STO_1A_24V (X1-14)