Connecting the REPLENISHMENT TUBES

Caution
• Prevent contaminating the processing solutions. Do the following procedure to connect the DEVELOPER
REPLENISHMENT TUBE to the DEVELOPER REPLENISHMENT TANK, then, do the same procedure to
connect the FIXER REPLENISHMENT TUBE.
• Use only thick-walled TUBING because the REPLENISHMENT PUMPS cause high suction.
[1] Locate the left or right KNOCKOUT in the feed end of the PROCESSOR, that you need to use for the
REPLENISHMENT TUBES. Remove the KNOCKOUT.
[2] Insert the REPLENISHMENT TUBE through the KNOCKOUT.
Note
The REPLENISHMENT TUBES are not provided with the PROCESSOR.

Connecting the REPLENISHMENT TANKS

Important
• Because this PROCESSOR has very high pumping rates, check that the TUBES are not bent or do not have
obstructions.
• Connect the developer REPLENISHMENT TUBE first, then, connect the fixer REPLENISHMENT TUBE.
[1] Install one end of the STRAINER into the TUBE from the REPLENISHMENT TANK.
[2] Install the other end of the STRAINER into the TUBE to the PROCESSOR.
[3] Connect the TUBE to the REPLENISHMENT INLET on the REPLENISHMENT PUMP.
[4] After following the above procedures for the installation of the developer REPLENISHMENT TUBE, do the
above procedures again for the installation of the fixer REPLENISHMENT TUBE.
Installing the REPLENISHMENT TUBES
KNOCKOUTS
H148_0025BCA
H148_0025BA
5B6339 – January 1996
DEVELOPER
REPLENISHMENT
INLET
REPLENISHMENT
TANK
STRAINER
Connecting the PROCESSOR
FIXER
REPLENISHMENT
INLET
31