Note
Remember that any values changed here will be overwritten by the configured
values the next time you restart.
AS-i Line 1 > Act −> Conf > Adopt Act −> Conf
With this function, you adopt the detected actual configuration of the slave as the
configured configuration on the IE/AS-i LINK.
WBM: "Total Configuration" Tab
The page is divided into two areas and includes all A and B slaves detected on this
line:
S Detected
Here, you can see all the slaves detected on this line including their detected
configuration (display boxes).
S Configured
Here, you can set the configuration data for the slaves.