Commissioning - drive-based
3.7 Safety overview
3.7.2

Safety Integrated overview

The most important information about the active safety functions is displayed in the "Overview"
window:
Figure 3-2
● Axis/drive
All NC axes and drives in the system are displayed in this column.
● Extended functions
This column displays whether and if yes, which extended functions are used for this axis
or this drive.
● Basic functions
This column displays as to whether a basic function is used for this axis or for this drive
and its associated control.
● Assignment
NC axis or internal Control Unit of the drive – or a drive object exists on the Control Unit,
to which an NC axis is assigned.
● SI start-up/commissioning mode
Indicates whether the commissioning mode is active for the drive.
● Status symbols
The parameters are evaluated through two channels. The status symbols indicate as to
whether the parameters are identical in both channels.
– Green: Parameterization identical in the 1st and 2nd monitoring channels
– Red: Parameterization different in the 1st and 2nd monitoring channels