4.3
Canceling the commissioning mode
The commissioning mode can be immediately exited if no safety parameters were changed.
If safety parameters were changed, before exiting the commissioning mode, it still has to be
defined what should happen with the modified safety parameters.
Procedure
Safety Integrated
Function Manual, 10/2015, 6FC5397-3EP40-5BA3
1.
You wish to cancel the commissioning mode.
Press the "Cancel" softkey.
Based on the checksums, the program checks as to whether safety pa‐
rameters were changed.
If this is not the case, then the commissioning mode is exited at this point.
- OR -
If the program identifies the parameters have been changed, then the
following prompt is displayed:
2a.
Objective: Confirm the changed data
Press the "OK" softkey to confirm the SI data of the actual TM54F and to
exit the commissioning mode. The actual checksum of the actual TM54F
is copied over to the reference checksum.
Commissioning - TM54F
4.3 Canceling the commissioning mode
97