Siemens SINUMERIK Series Function Manual page 101

Safety integrated
Hide thumbs Also See for SINUMERIK Series:
Table of Contents

Advertisement

Alternatively 2c.
See also
Copying or confirming SI data (Page 54)
Safety Integrated
Function Manual, 10/2015, 6FC5397-3EP40-5BA3
If you do not wish to duplicate the SI data from the master to the slave,
then proceed as follows:
Press the "OK" softkey.
The modified SI data of the TM54F master are copied to the TM54F slave.
- OR -
Press the "Copy all TM54F" softkey.
The modified SI data of all TM54F devices, which are in the commission‐
ing mode, are copied to the TM54F slave.
This softkey is only visible if there are several TM54F devices are in your
drive system.
For both copy options, a prompt is then issued for subsequent actions,
which are necessary to exit the commissioning mode.
Press the "OK" softkey.
As a consequence, the SI data of the actual TM54F are confirmed, and
the commissioning mode is exited.
- OR -
Press the "Confirm all TM54F" softkey.
As a consequence, the SI data of all TM54F is confirmed and the com‐
missioning mode is then exited.
This softkey is only visible if there are several TM54F devices are in your
drive system.
- OR -
Press the "Reset (po)" softkey.
This means that all changes to the SI data are undone. The NCK and the
complete drive system is then restarted.
Objective: Remain in the commissioning mode
Press the "Cancel" softkey in order to close the window that has just been
opened without any interaction. The previous window is displayed again.
Commissioning - TM54F
4.4 Exit the commissioning mode
101