Commissioning - TM54F

4.5 Configuring the TM54F

4.5
Configuring the TM54F
4.5.1

Calling the configuration range

Figure 4-2
Procedure
102
Example: TM54F configuration
You can open the required configuration range after you have activated
the commissioning mode (Page 95) for TM54F.
1.
For each TM54F, the 4 configuration ranges can be called using softkeys
with the same name.
Press the appropriate softkey:
● "Configuration"
● "Inputs"
● "Outputs"
● "Drive groups"
...
Displaying TM54F checksums
2.
Press the "Checksums" softkey to display the checksums for the TM54F
configuration area in a window (see TM54F checksums (Page 111)).