Commissioning - application example
6.3 Parameterizing the TM54F
6.3.3
TM54F terminal description
Wiring the TM54F
The logic is established with this hardware, which is shown as example in Chapter "From the
function table to the logic diagram (Page 134)". The inputs should be wired with two channels.
The 24 V power supply for the inputs is important, in order that the forced checking procedure
can be performed.
144
Function Manual, 10/2015, 6FC5397-3EP40-5BA3
Safety Integrated